Build it step by step
0 of 7 doneMount the load cell
One end fixed to a base, the other end carrying a small platform, with spacers so it can flex.
Wire the programmer
SWDIO, SWCLK, GND and 3.3V.
Wire the amplifier
DT to PA0, SCK to PA1, power at 3.3 V.
Wire the load cell
Red to E+, black to E-, white to A-, green to A+.
Wire the display and button
OLED on PB7 and PB6, button on PB12 to GND.
Install the libraries
HX711, Adafruit SSD1306 and Adafruit GFX.
Upload and calibrate
With the platform empty press tare, put the known weight on, type c500 in the Serial Monitor.
How do you build a blue Pill kitchen scale?
A Blue Pill reads a 5 kg bar load cell through an HX711 amplifier, tares on a button and shows grams on an OLED, with a serial command to calibrate against a known weight. You need STM32 Blue Pill (STM32F103C8T6), ST-Link V2 programmer (clone), HX711 load cell amplifier, Load cell 5 kg (bar type), SSD1306 OLED Display, Tactile push button 6 mm and Breadboard 830 Tie Points. It takes 7 steps and about 170 minutes.
- Level
- Intermediate
- Time
- About 170 min
- Parts
- 7
Parts list
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| ST-Link GND | Board GND | Ground |
| ST-Link SWDIO | Board DIO | Debug data |
| ST-Link SWCLK | Board DCLK | Debug clock |
| ST-Link 3.3V | Board 3.3 pin | Power from the programmer (do not also plug in USB) |
| HX711 VCC and OLED VCC | Blue Pill 3.3 pin | Power at 3.3 V |
| HX711 GND and OLED GND | Blue Pill GND | Common ground |
| HX711 DT | Blue Pill PA0 | Data from the amplifier |
| HX711 SCK | Blue Pill PA1 | Clock to the amplifier |
| Load cell red wire | HX711 E+ | Excitation positive (check your cell's sheet) |
| Load cell black wire | HX711 E- | Excitation negative |
| Load cell white wire | HX711 A- | Signal negative |
| Load cell green wire | HX711 A+ | Signal positive |
| OLED SDA and SCL | Blue Pill PB7 and PB6 | I2C data and clock |
| Tare button | Blue Pill PB12 and GND | Sets zero |
Code
A load cell is a metal bar with strain gauges glued on it. When you press on it the bar bends by a tiny amount and the gauges change resistance, which unbalances a small bridge circuit and gives a voltage of only a few millivolts. The HX711 is a 24-bit converter with a built-in amplifier made for exactly this, and it sends the result to the board over two wires, a data line and a clock line. The program reads a raw count, and the count is proportional to the weight once you subtract the empty reading, which is what the tare button does. To turn counts into grams you need one number, counts per gram. You find it by putting a known weight on the scale and typing it in; the program works out the factor and uses it from then on. Note the factor and put it in the sketch so it survives a restart. Mount the bar so that one end is fixed to the base and the other end carries the platform, with small spacers so the bar can flex, and never load it beyond its 5 kg rating.
Runs on a virtual STM32 Blue Pill in your browser, with sliders for the sensors. Happy with it? Verify and upload to your real board from the same page (Chrome or Edge on a computer).
#include <Wire.h>
#include <HX711.h>
#include <Adafruit_GFX.h>
#include <Adafruit_SSD1306.h>
const int DT = PA0, SCK_PIN = PA1, TARE_BTN = PB12;
HX711 scale;
Adafruit_SSD1306 oled(128, 64, &Wire, -1);
float factor = 420.0; // counts per gram, replaced when you calibrate
unsigned long lastDraw = 0;
void showGrams(float g) {
oled.clearDisplay();
oled.setTextColor(SSD1306_WHITE);
oled.setTextSize(1);
oled.setCursor(0, 0);
oled.print("Load cell scale");
oled.setTextSize(3);
oled.setCursor(0, 24);
oled.print(g, 0);
oled.setTextSize(2);
oled.print(" g");
oled.display();
}
void setup() {
Serial.begin(115200);
pinMode(TARE_BTN, INPUT_PULLUP);
Wire.begin(); // I2C1 uses PB7 for SDA and PB6 for SCL
if (!oled.begin(SSD1306_SWITCHCAPVCC, 0x3C)) { while (true) {} }
scale.begin(DT, SCK_PIN);
scale.set_scale(factor);
while (!scale.is_ready()) { delay(50); }
scale.tare(); // start with nothing on the scale
Serial.println("Type c and the weight in grams, for example c500, with that weight on the scale.");
}
void loop() {
if (digitalRead(TARE_BTN) == LOW) {
scale.tare();
delay(300);
}
if (Serial.available()) {
String line = Serial.readStringUntil('\n');
if (line.length() > 1 && line[0] == 'c') {
float known = line.substring(1).toFloat();
float raw = scale.get_value(10); // reading minus the tare offset
if (known > 0 && raw != 0) {
factor = raw / known;
scale.set_scale(factor);
Serial.print("Calibration factor ");
Serial.println(factor, 2); // note this number to use as the starting value
}
}
}
if (millis() - lastDraw >= 250 && scale.is_ready()) {
lastDraw = millis();
float g = scale.get_units(3);
if (fabs(g) < 0.5) g = 0; // hide tiny noise around zero
showGrams(g);
}
}Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| Empty platform | Shows 0 g after tare |
| Known weight on the platform | Shows its weight within a few grams after calibration |
| Weight removed | Returns to about 0 g |
| Press tare with a cup on the platform | Shows 0 g, then the contents of the cup when you add water |
| Press down on the platform by hand | Reading rises, release and it returns |
If it does not work
Reading goes negative when you add weight
Swap the green and white wires at A+ and A-.
Reading drifts
Let the board warm up for a few minutes and keep the cell out of draughts and sunlight.
Reading jumps around
Keep the wires short and away from the display wires, and check the cell is firmly fixed at the fixed end.
Weight is wrong by a constant ratio
Calibrate again with a known weight.
Nothing on the display
Check the I2C wires and that the OLED address is 0x3C.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the blue Pill kitchen scale?
STM32 Blue Pill (STM32F103C8T6), ST-Link V2 programmer (clone), HX711 load cell amplifier, Load cell 5 kg (bar type), SSD1306 OLED Display, Tactile push button 6 mm and Breadboard 830 Tie Points.
How long does the blue Pill kitchen scale take to build?
About 170 minutes for a intermediate maker, in 7 steps.
How do I know the blue Pill kitchen scale works?
Empty platform: Shows 0 g after tare. Known weight on the platform: Shows its weight within a few grams after calibration. Weight removed: Returns to about 0 g.
Reading goes negative when you add weight: what should I check?
Swap the green and white wires at A+ and A-.
Reading drifts: what should I check?
Let the board warm up for a few minutes and keep the cell out of draughts and sunlight.
Reading jumps around: what should I check?
Keep the wires short and away from the display wires, and check the cell is firmly fixed at the fixed end.
Weight is wrong by a constant ratio: what should I check?
Calibrate again with a known weight.