Fault finder: Blue Pill kitchen scale
11 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Reading goes negative when you add weight: what should I check?
Swap the green and white wires at A+ and A-.
Reading drifts: what should I check?
Let the board warm up for a few minutes and keep the cell out of draughts and sunlight.
Reading jumps around: what should I check?
Keep the wires short and away from the display wires, and check the cell is firmly fixed at the fixed end.
Weight is wrong by a constant ratio: what should I check?
Calibrate again with a known weight.
Nothing on the display: what should I check?
Check the I2C wires and that the OLED address is 0x3C.