Fault finder: Blue Pill kitchen scale

11 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Reading goes negative when you add weight: what should I check?

Swap the green and white wires at A+ and A-.

Reading drifts: what should I check?

Let the board warm up for a few minutes and keep the cell out of draughts and sunlight.

Reading jumps around: what should I check?

Keep the wires short and away from the display wires, and check the cell is firmly fixed at the fixed end.

Weight is wrong by a constant ratio: what should I check?

Calibrate again with a known weight.

Nothing on the display: what should I check?

Check the I2C wires and that the OLED address is 0x3C.