Lab / Virtual lab / Op-amps, timers and oscillators

555 astable multivibrator

See how RA, RB and C set the frequency and duty cycle.

Op-amps, timers and oscillatorsSimulatedFull experiment write-up →

Circuit

Updates as you change values
555+5 V76, 2RA 10 kΩRB 10 kΩC 1 µF3

A 555 in astable mode on 5 V; read the frequency and duty cycle on the CRO.

Controls

Changing any setting except rb starts a new set of readings.

Meters

Frequency48 Hz
Duty66.7 %

Graph

0 readings

Your graph appears here

Take readings, or press Auto sweep to log a full set.

your readings

Theory

  • f = 1.44 / ((RA + 2RB) C)
  • tHIGH = 0.693 (RA + RB) C, tLOW = 0.693 RB C
  • Duty = (RA + RB) / (RA + 2RB): always above 50 %
  • C charges between VCC/3 and 2VCC/3 (ln 2 = 0.693)
  • For under 50 % duty, put a diode across RB

Worked out for your values

Frequency
48.1 Hz
tHIGH
13.86 ms
tLOW
6.93 ms
Duty
66.7 %

Your result

Worked out from your readings and compared with theory.

C from the slope of 1/f against RB

Take two or more readings at different RB.

Sources of error

  • Timing capacitor tolerance (±10–20 %)
  • The 1.44 constant assumes ideal thresholds
  • Discharge transistor saturation voltage at small RB