Lab / Virtual lab / Op-amps, timers and oscillators
555 astable multivibrator
See how RA, RB and C set the frequency and duty cycle.
Circuit
Updates as you change valuesA 555 in astable mode on 5 V; read the frequency and duty cycle on the CRO.
Controls
Changing any setting except rb starts a new set of readings.
Meters
Frequency48 Hz
Duty66.7 %
Graph
0 readingsYour graph appears here
Take readings, or press Auto sweep to log a full set.
your readings
Theory
- f = 1.44 / ((RA + 2RB) C)
- tHIGH = 0.693 (RA + RB) C, tLOW = 0.693 RB C
- Duty = (RA + RB) / (RA + 2RB): always above 50 %
- C charges between VCC/3 and 2VCC/3 (ln 2 = 0.693)
- For under 50 % duty, put a diode across RB
Worked out for your values
- Frequency
- 48.1 Hz
- tHIGH
- 13.86 ms
- tLOW
- 6.93 ms
- Duty
- 66.7 %
Your result
Worked out from your readings and compared with theory.
C from the slope of 1/f against RB
Take two or more readings at different RB.
Sources of error
- Timing capacitor tolerance (±10–20 %)
- The 1.44 constant assumes ideal thresholds
- Discharge transistor saturation voltage at small RB
More in Op-amps, timers and oscillators