Lab / Virtual lab / Op-amps, timers and oscillators

Schmitt trigger and hysteresis

Sweep the input up then down and find the two switching thresholds of an op-amp Schmitt trigger.

Op-amps, timers and oscillatorsSimulatedFull experiment write-up →

Circuit

Updates as you change values
−+VOVin10 kΩ10 kΩ

A 741 on ±15 V (output saturates at about ±13 V) with positive feedback R2 from the output and R1 to ground; slowly raise, then lower, the input and read the output.

Controls

Changing any setting except input voltage or sweep direction starts a new set of readings. Changing sweep direction keeps them, so you can compare curves.

Meters

Output13 V

Graph

0 readings

Your graph appears here

Take readings, or press Auto sweep to log a full set.

your readings other sweep direction

Theory

  • Feedback fraction β = R1 / (R1 + R2), R1 = 10 kΩ
  • Upper threshold UTP = +β Vsat, lower threshold LTP = −β Vsat
  • Hysteresis width VH = UTP − LTP = 2 β Vsat
  • Rising input: output flips low at UTP; falling input: flips high at LTP
  • Hysteresis stops the output chattering when noise rides on a slow input

Worked out for your values

β
0.500
Upper threshold UTP
6.5 V
Lower threshold LTP
-6.5 V
Hysteresis width
13 V

Your result

Worked out from your readings and compared with theory.

UTP: where the rising sweep flips

Take readings on a rising sweep either side of the threshold.

LTP: where the falling sweep flips

Take readings on a falling sweep either side of the threshold.

Hysteresis width UTP − LTP

Take both sweeps.

Sources of error

  • Saturation voltage is below the supply and differs for + and −
  • Op-amp slew rate slows the flip
  • Take the sweep slowly; a fast sweep hides the loop