Schmitt trigger and hysteresis
Sweep the input up then down and find the two switching thresholds of an op-amp Schmitt trigger.
Circuit
Updates as you change valuesA 741 on ±15 V (output saturates at about ±13 V) with positive feedback R2 from the output and R1 to ground; slowly raise, then lower, the input and read the output.
Controls
Changing any setting except input voltage or sweep direction starts a new set of readings. Changing sweep direction keeps them, so you can compare curves.
Meters
Graph
0 readingsYour graph appears here
Take readings, or press Auto sweep to log a full set.
Theory
- Feedback fraction β = R1 / (R1 + R2), R1 = 10 kΩ
- Upper threshold UTP = +β Vsat, lower threshold LTP = −β Vsat
- Hysteresis width VH = UTP − LTP = 2 β Vsat
- Rising input: output flips low at UTP; falling input: flips high at LTP
- Hysteresis stops the output chattering when noise rides on a slow input
Worked out for your values
- β
- 0.500
- Upper threshold UTP
- 6.5 V
- Lower threshold LTP
- -6.5 V
- Hysteresis width
- 13 V
Your result
Worked out from your readings and compared with theory.
UTP: where the rising sweep flips
Take readings on a rising sweep either side of the threshold.
LTP: where the falling sweep flips
Take readings on a falling sweep either side of the threshold.
Hysteresis width UTP − LTP
Take both sweeps.
Sources of error
- Saturation voltage is below the supply and differs for + and −
- Op-amp slew rate slows the flip
- Take the sweep slowly; a fast sweep hides the loop
More in Op-amps, timers and oscillators