Schmitt trigger using an op-amp
To build an inverting Schmitt trigger and measure its upper and lower trip points and hysteresis.
Theory
A Schmitt trigger is a comparator with positive feedback. In the inverting version the reference at pin 3 is β·Vsat, with β = R2/(R1 + R2). The output switches low when the input rises above UTP = +β·Vsat and high again when it falls below LTP = −β·Vsat. The difference UTP − LTP is the hysteresis, which stops noisy inputs from causing many switchings.
Apparatus
- IC 741
- Resistors R1 10 kΩ, R2 2.2 kΩ
- Dual supply ±12 V
- Function generator
- CRO
Circuit connections
- Input → pin 2; R1 from pin 6 (output) to pin 3; R2 from pin 3 to ground
Procedure
Pre-lab check
4 questions · 75% to be readyTry the readings before the lab
| Quantity | Value (V) |
|---|---|
| β = R2 / (R1 + R2) | 0.18 |
| UTP | 1.89 |
| LTP | -1.89 |
| Hysteresis | 3.79 |
Precautions
- Use an input amplitude larger than UTP.
- Use DC coupling for both channels.
My readings
Type what you measured. It goes into your record book, and to My Garage when you are signed in.
| S. No. | Quantity | Value (V) |
|---|---|---|
| 1 | ||
| 2 | ||
| 3 | ||
| 4 | ||
| 5 | ||
| 6 |
Check my readings
Put the value you set in the first column, then compare. Real parts have tolerance.
Your lab record
Everything above is free. The print-ready write-up comes with Maker.
Printed pages leave the observation table empty for your own readings.
Viva practice
Say your answer out loud first, then check. The first 2 answers are free; Maker opens all 4.
Quick answers for your record and viva
What is the aim of the schmitt trigger using an op-amp experiment?
To build an inverting Schmitt trigger and measure its upper and lower trip points and hysteresis.
What apparatus is needed for schmitt trigger using an op-amp?
IC 741, Resistors R1 10 kΩ, R2 2.2 kΩ, Dual supply ±12 V, Function generator, CRO.
What is the theory behind schmitt trigger using an op-amp?
A Schmitt trigger is a comparator with positive feedback. In the inverting version the reference at pin 3 is β·Vsat, with β = R2/(R1 + R2). The output switches low when the input rises above UTP = +β·Vsat and high again when it falls below LTP = −β·Vsat. The difference UTP − LTP is the hysteresis, which stops noisy inputs from causing many switchings.
What result should I get in schmitt trigger using an op-amp?
UTP = ___ V, LTP = ___ V, hysteresis = ___ V, close to the calculated values.
What precautions should I take in schmitt trigger using an op-amp?
Use an input amplitude larger than UTP. Use DC coupling for both channels.