Final-year projects / Power systems

Underground cable fault distance locator

Cities are moving power lines underground, but finding a fault in a buried cable means digging up long stretches. Measuring the resistance to the fault from one end tells the crew how many metres away to dig.

Arduino UnoMini or Major projectEEE, ECE, Diploma
UNOONHelloLCDFeatured
Parts
₹3,204
Build
12 weeks
Board
Arduino Uno
Objectives
6

Block diagram

Inputs
  • Resistor cable modelEach 1 kΩ stands for 1 km of cable
  • Fault switchesCreate short and open faults
Controller
  • UNO
    Arduino UnoMeasures voltage and works out distance
Outputs
  • ON
    RelaysSelect each phase in turn
  • 23.4°CLCD
    LCDShows phase and distance
  • 4G
    4G modemSends SMS alerts and calls over the mobile network+
  • CLOUD
    Cloud dashboardStores readings, plots trends and sends alerts+

Objectives

  1. To model a three-phase cable 4 km long with resistors and switchable faults.
  2. To find which phase has the fault and its distance in km from the measured voltage.
  3. To tell a short-circuit fault from an open-circuit fault.
  4. To measure the distance error for every fault position.
  5. To send SMS alerts through a 4G modem where no Wi-Fi is available.
  6. To publish readings over MQTT and show them on a live dashboard with threshold alerts.

Parts and specifications

Total about ₹3,204 at typical online prices. Tap a part for its pinout and datasheet notes.

Design calculations

Voltage to resistance

The series resistor Rs and the cable to the fault form a divider: V = 5 × Rf / (Rs + Rf), so Rf = Rs × V / (5 − V).

Resistance to distance

Each 1 kΩ in the model is 1 km. A short at 3 km gives Rf = 3 kΩ: V = 5 × 3 / 4 = 3.75 V, and back Rf = 1 × 3.75 / 1.25 = 3 kΩ = 3 km.

Resolution

Between 3 km (3.75 V) and 4 km (4.0 V) the step is 250 mV. A 10-bit ADC step is 4.9 mV and the ADS1115 0.19 mV, so both resolve 1 km easily; finer steps need the 16-bit ADC.

Real cables

A real 95 mm² aluminium core is about 0.32 Ω per km, so field locators use a bridge (Murray loop) or time-domain reflectometry, not a simple divider.

Pin map

SignalPin or connection
ADS1115 SDA / SCLA4 / A5 (or A0 direct for the basic version)
Phase R / Y / B select relaysD2 / D3 / D4
LCD SDA / SCLA4 / A5 (shared I²C)
Measuring series resistor1 kΩ 1% from 5 V to the selected phase

Firmware outline

  1. Select phase R with its relay, wait 50 ms, read the voltage (average 16 samples).
  2. If V is near 5 V, no fault on this phase (open line or healthy).
  3. Else compute Rf and the distance, rounded to the nearest km.
  4. Repeat for Y and B; show 'R: 2 km Y: ok B: 4 km' on the LCD.
  5. Report an open fault when the far-end loop resistance is missing.

Test plan

TestExpected result
Short at each of 1 to 4 km on each phaseCorrect phase and distance
No faultAll phases ok
Two faults on different phasesBoth found
Resistor tolerance 5% vs 1%Distance error compared

These rows start your results table when you plan the project.

Viva practice

Say your answer out loud first, then check. The first 2 answers are free; Maker opens all 5.

1. Why does a simple divider work in the model?
2. How are real cable faults located?
3. What is TDR?
4. Why scan phases with relays?
5. What causes underground cable faults?

Make it yours

One or two upgrades for a mini project, two to four for a major one.

Build these first

Datasheets and sources to cite

  • Murray and Varley loop test (IEEE Std 400 guide on cable fault location)
  • Microchip ATmega328P datasheet
  • TI ADS1115 datasheet

About this project

How much does the underground cable fault distance locator project cost?

About ₹1,614 for the parts in the base list: Arduino Uno R3 (CH340 clone), 5 V relay module (4 channel), 16×2 LCD with I²C backpack, 1 kΩ 1% resistors (cable model, 3 phases × 4 km) × 12, Fault toggle switches × 12, Zero PCB 10 × 15 cm × 2, ADS1115 16-bit ADC (better resolution), 5 V 2 A adapter.

How long does it take?

About 8 weeks for the base project, built on an Arduino Uno. Each upgrade adds time.

Which branches is it suitable for?

Electrical and Electronics, Electronics and Communication, Diploma (any electronics branch), as a mini or major project.

Which pins and design calculations does it use?

ADS1115 SDA / SCL on A4 / A5 (or A0 direct for the basic version); Phase R / Y / B select relays on D2 / D3 / D4; LCD SDA / SCL on A4 / A5 (shared I²C). Worked calculations on this page: voltage to resistance, resistance to distance, resolution, real cables.

How do I test it?

Short at each of 1 to 4 km on each phase: Correct phase and distance. No fault: All phases ok. Two faults on different phases: Both found. Resistor tolerance 5% vs 1%: Distance error compared.

What are the objectives?

To model a three-phase cable 4 km long with resistors and switchable faults. To find which phase has the fault and its distance in km from the measured voltage. To tell a short-circuit fault from an open-circuit fault. To measure the distance error for every fault position.