Build it step by step
0 of 9 doneBuild the network
Wire R1 and R2 from the 9 V battery.
Measure the open-circuit voltage
Read between A and B with nothing attached.
Measure the short-circuit current
Set the meter to mA and join A to B through it, briefly.
Work out Rth
Divide the open-circuit voltage by the short-circuit current.
Check by calculation
R1 in parallel with R2 should match.
Add a load
Put the 4.7 kΩ across A and B and measure the voltage.
Compare
Work out the voltage a 6.19 V source with Rth would give across 4.7 kΩ and compare.
Try the pot
Use it as a variable load and find where output power is greatest, at a resistance near Rth.
Try the thermistor
Replace R2 with the 10 kΩ NTC and see the open-circuit voltage and Thevenin resistance change as you warm it with your fingers.
How do you build a thevenin equivalent lab?
Measure open-circuit voltage and short-circuit current of a network and replace it with one source and resistor. You need Digital multimeter, Resistor 1 kΩ, Resistor 2.2 kΩ, Resistor 4.7 kΩ, Potentiometer 10 kΩ, NTC thermistor 10 kΩ (B3950), Breadboard 830 Tie Points, Jumper wires male to male (40 pcs, 20 cm), 9 V battery and 9 V battery snap with DC jack. It takes 9 steps and about 60 minutes.
- Level
- Intermediate
- Time
- About 60 min
- Parts
- 10
Parts list
- Tools & InstrumentsBuy
- PassivesBuyResistor 1 kΩ × 1
- PassivesBuyResistor 2.2 kΩ × 1
- PassivesBuyResistor 4.7 kΩ × 1
- PassivesBuy
- SensorsBuy
- PrototypingBuy
- PrototypingBuy
- BatteriesBuy9 V battery × 1
- PowerBuy
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| Battery + | 1 kΩ resistor R1 | Source side |
| R1 other end | Output terminal A and 2.2 kΩ resistor R2 | Network output |
| R2 other end | Output terminal B and battery - | Return |
| 4.7 kΩ resistor | Between A and B for the load check | Test load |
| Multimeter | Across A and B for voltage, in series between A and B for current | Measurements |
No code needed
No code. The network is a 9 V source with R1 = 1 kΩ in series and R2 = 2.2 kΩ across the output. The open-circuit voltage at A and B is about 9 × 2.2 ÷ 3.2 = 6.19 V. The short-circuit current, with the meter on the mA range directly across A and B, is about 9 mA, which is safe for the meter range. The Thevenin resistance is the open-circuit voltage divided by the short-circuit current, about 0.69 kΩ, which is also R1 and R2 in parallel. Then the whole network behaves like a 6.19 V source with 0.69 kΩ in series, and a 4.7 kΩ load should read about 5.4 V across it either way. Use a fresh meter fuse range for the short-circuit step and keep it short.
Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| Open-circuit voltage | About 6.2 V |
| Short-circuit current | About 9 mA |
| Thevenin resistance | About 0.69 kΩ |
| 4.7 kΩ load voltage | About 5.4 V both by measurement and by the equivalent |
If it does not work
Short-circuit reads low
The meter has some resistance on the mA range; allow for a small error.
Meter reads zero current
Wrong socket or a blown fuse.
Numbers differ from the example
Use your measured battery voltage and resistor values.
Battery drops under load
Use a fresh battery.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the thevenin equivalent lab?
Digital multimeter, Resistor 1 kΩ, Resistor 2.2 kΩ, Resistor 4.7 kΩ, Potentiometer 10 kΩ, NTC thermistor 10 kΩ (B3950), Breadboard 830 Tie Points, Jumper wires male to male (40 pcs, 20 cm), 9 V battery and 9 V battery snap with DC jack.
How long does the thevenin equivalent lab take to build?
About 60 minutes for a intermediate maker, in 9 steps.
How do I know the thevenin equivalent lab works?
Open-circuit voltage: About 6.2 V. Short-circuit current: About 9 mA. Thevenin resistance: About 0.69 kΩ.
Short-circuit reads low: what should I check?
The meter has some resistance on the mA range; allow for a small error.
Meter reads zero current: what should I check?
Wrong socket or a blown fuse.
Numbers differ from the example: what should I check?
Use your measured battery voltage and resistor values.
Battery drops under load: what should I check?
Use a fresh battery.