RC time constant with a stopwatch
Build it step by step
0 of 8 doneMeasure the supply
Note Vs and work out 63 percent.
Build the circuit
100 kilohm to the 22 uF capacitor.
Discharge the capacitor
1 kilohm across it until under 0.1 V.
Start the timer
Connect the supply and start the stopwatch.
Stop at the target
When the meter reads 63 percent.
Swap capacitors
Repeat with 47 uF.
Join them in parallel
Time the 69 uF case.
Compare
Measured times against 2.2, 4.7 and 6.9 s.
How do you build an RC time constant with a stopwatch?
Charge capacitors of different values through the same resistor and time how long each takes to reach 63 percent. You need Electrolytic capacitor 22 µF, Electrolytic capacitor 47 µF, Resistor 100 kΩ, Resistor 1 kΩ, 5 V 2 A USB adapter, Digital multimeter, Jumper wires male to male (40 pcs, 20 cm) and Breadboard 830 Tie Points. It takes 8 steps and about 75 minutes.
- Level
- Beginner
- Time
- About 75 min
- Parts
- 8
Parts list
- PassivesBuy
- PassivesBuy
- PassivesBuyResistor 100 kΩ × 1
- PassivesBuyResistor 1 kΩ × 1
- PowerBuy
- Tools & InstrumentsBuy
- PrototypingBuy
- PrototypingBuy
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| 5 V adapter positive | 100 kilohm resistor | Charging resistor |
| 100 kilohm resistor | Capacitor positive leg (long leg) | Capacitor under test |
| Capacitor negative leg (striped side) | 5 V adapter negative | Return |
| Multimeter red probe | Capacitor positive leg | Reads the capacitor voltage |
| Multimeter black probe | Capacitor negative leg | Common ground |
| 1 kilohm resistor | Across the capacitor, used briefly | Safe discharge between runs |
Code
Every capacitor and resistor pair has a time constant, the product of the resistance and the capacitance, and it controls how fast the capacitor charges or discharges. After one time constant the capacitor has reached about 63 percent of the supply voltage, and after about three it is nearly full. This is slow enough with a 100 kilohm resistor and microfarad-sized capacitors that you can time it with a phone stopwatch and read the voltage on a multimeter. The three tests give different times: 22 microfarads should take about 2.2 seconds, 47 microfarads about 4.7, and putting the two in parallel, which adds their capacitance, about 6.9. Measure the real supply voltage first and work out the 63 percent target from it, then start the stopwatch as you connect the supply and stop it when the meter hits the target. Do each test a few times and average, because starting and stopping by hand is only good to a few tenths of a second. Electrolytic capacitors are often 20 percent away from their label, so do not worry if your times are not exact: that is a lesson in itself. Always discharge the capacitor between tests through the 1 kilohm resistor, keep the polarity right, and stay at 5 volts, well below the rating on the capacitor.
Build notes (no code needed for this build) An RC circuit charges the capacitor towards the supply: V(t) = Vs x (1 - e^(-t / RC)). After one time constant, t = R x C, the voltage reaches 63.2 percent of the supply. After 3 time constants it is about 95 percent. Calculated time constants with R = 100 kilohm: 22 uF : RC = 100k x 22 uF = 2.2 s 47 uF : RC = 4.7 s 22 + 47 uF in parallel (69 uF) : RC = 6.9 s (capacitors in parallel add) Method for each capacitor: 1. Measure your actual supply voltage Vs with the meter, for example 5.05 V. 2. Compute the target: 0.632 x Vs, for example 3.19 V. 3. Discharge the capacitor with the 1 kilohm resistor across it until the meter reads under 0.1 V. 4. Remove the discharge resistor, start the stopwatch as you connect the supply, and stop it when the meter reads the target. 5. Repeat three times and average. Expect the measured time to be within about 20 percent of the calculation, because electrolytic capacitors are often 20 percent off their label, and a meter loads the circuit slightly. Keep the capacitor the right way round, positive leg to the resistor side, and use a 5 V supply well under the rating printed on the can. Do not use a larger voltage than the capacitor rating.
Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| 22 uF | About 2.2 s, allow plus or minus 20 percent |
| 47 uF | About 4.7 s |
| 22 uF and 47 uF in parallel | About 6.9 s |
| Voltage after three time constants | About 95 percent of the supply |
| Meter loading | Small effect, a few percent |
If it does not work
Time much too short
The capacitor was not fully discharged.
Time much too long
Check the resistor is 100 kilohm and the capacitance is right.
Voltage never reaches the target
Leakage or a faulty capacitor, try another.
Reading looks backwards
Check the capacitor polarity.
Times vary
Average three runs and use the same meter range.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the RC time constant with a stopwatch?
Electrolytic capacitor 22 µF, Electrolytic capacitor 47 µF, Resistor 100 kΩ, Resistor 1 kΩ, 5 V 2 A USB adapter, Digital multimeter, Jumper wires male to male (40 pcs, 20 cm) and Breadboard 830 Tie Points.
How long does the RC time constant with a stopwatch take to build?
About 75 minutes for a beginner maker, in 8 steps.
How do I know the RC time constant with a stopwatch works?
22 uF: About 2.2 s, allow plus or minus 20 percent. 47 uF: About 4.7 s. 22 uF and 47 uF in parallel: About 6.9 s.
Time much too short: what should I check?
The capacitor was not fully discharged.
Time much too long: what should I check?
Check the resistor is 100 kilohm and the capacitance is right.
Voltage never reaches the target: what should I check?
Leakage or a faulty capacitor, try another.
Reading looks backwards: what should I check?
Check the capacitor polarity.