Fault finder: RC time constant with a stopwatch
6 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 6 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 6
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Time much too short: what should I check?
The capacitor was not fully discharged.
Time much too long: what should I check?
Check the resistor is 100 kilohm and the capacitance is right.
Voltage never reaches the target: what should I check?
Leakage or a faulty capacitor, try another.
Reading looks backwards: what should I check?
Check the capacitor polarity.
Times vary: what should I check?
Average three runs and use the same meter range.