Build it step by step
0 of 7 doneWire the input side
Battery A, button, 1 kΩ and the LED inside the PC817.
Wire the output side
Battery B, red LED, 330 Ω and the transistor side, with no link to battery A.
Press the button
The red LED should light with no wire between the two sides.
Measure the input current
Put a meter in series on the input side: expect about 8 mA.
Measure the output current
Put the meter in series with the red LED: expect about 6 to 20 mA.
Work out the CTR
CTR % = output current ÷ input current × 100.
Check isolation
With a meter on resistance, measure between the two grounds and find an open circuit.
How do you build an optocoupler isolation lab?
Pass a signal across a PC817 with no electrical connection and measure its current transfer ratio. You need Optocoupler PC817, Resistor 330 Ω, Resistor 1 kΩ, LED 5 mm red, Tactile push button 6 mm, Digital multimeter, Breadboard 830 Tie Points, 9 V battery × 2 and 9 V battery snap with DC jack × 2. It takes 7 steps and about 45 minutes.
- Level
- Beginner
- Time
- About 45 min
- Parts
- 9
Parts list
- SemiconductorsBuy
- PassivesBuyResistor 330 Ω × 1
- PassivesBuyResistor 1 kΩ × 1
- SemiconductorsBuyLED 5 mm red × 1
- SwitchesBuy
- Tools & InstrumentsBuy
- PrototypingBuy
- BatteriesBuy9 V battery × 2
- PowerBuy
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| Battery A + (9 V) | Button, then 1 kΩ resistor | Input side supply |
| 1 kΩ resistor | PC817 pin 1 (anode) | Sets LED current to about 8 mA |
| PC817 pin 2 (cathode) | Battery A - | Input side ground only |
| Battery B + (9 V) | Red LED anode | Output side supply, separate battery |
| Red LED cathode | 330 Ω resistor, then PC817 pin 4 (collector) | Output transistor |
| PC817 pin 3 (emitter) | Battery B - | Output side ground only |
No code needed
No code. Use two separate batteries and never join the two grounds: that is what makes it isolated. The PC817 pins, with the dot at top left, are 1 anode, 2 cathode on the left (top to bottom) and 4 collector, 3 emitter on the right (top to bottom). Only use batteries; the isolation is for learning, not for connecting mains.
Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| Button released | LED off |
| Button pressed | LED on |
| Meter between the two grounds | Open circuit |
| CTR | Between about 50 % and 150 % (PC817 is rated 50 to 600 %) |
If it does not work
LED never lights
Check the PC817 orientation and that the input LED side has current.
LED always on
The output side is wired to the input battery. Keep them separate.
Very dim
Output transistor is saturated or the LED is wrong way round.
CTR is out of range
The transistor may saturate at high current. Use a larger output resistor.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the optocoupler isolation lab?
Optocoupler PC817, Resistor 330 Ω, Resistor 1 kΩ, LED 5 mm red, Tactile push button 6 mm, Digital multimeter, Breadboard 830 Tie Points, 9 V battery × 2 and 9 V battery snap with DC jack × 2.
How long does the optocoupler isolation lab take to build?
About 45 minutes for a beginner maker, in 7 steps.
How do I know the optocoupler isolation lab works?
Button released: LED off. Button pressed: LED on. Meter between the two grounds: Open circuit.
LED never lights: what should I check?
Check the PC817 orientation and that the input LED side has current.
LED always on: what should I check?
The output side is wired to the input battery. Keep them separate.
Very dim: what should I check?
Output transistor is saturated or the LED is wrong way round.
CTR is out of range: what should I check?
The transistor may saturate at high current. Use a larger output resistor.