Projects / ESD wrist strap tester

ESD wrist strap tester

Intermediate1 hGuided buildReviewed

Build it step by step

0 of 7 done
  1. Build the ladder

    Three resistor groups from rail to ground.

  2. Measure the taps

    About 8.1 V and 4.1 V.

  3. LM393

    Add the comparators

    LM393 as a window.

  4. 11.8 mA

    Add the LEDs

    Green good, red fail.

  5. Add the sense node

    1 MΩ and a pad.

  6. Test with resistors

    1 MΩ passes, 100 kΩ and open fail.

  7. 4.98V

    Test your strap

    Daily check.

In short

How do you build an ESD wrist strap tester?

Test that your ESD strap has the right resistance to ground before you start work. You need Anti-static wrist strap, LM393 Comparator, Resistor 1 kΩ × 2, Resistor 1 MΩ × 2, LED 5 mm green, LED 5 mm red, Resistor 330 Ω × 2, Tactile push button 6 mm, 9 V battery, 9 V battery snap with DC jack, Resistor 10 kΩ × 6, Resistor 4.7 kΩ and Resistor 2 kΩ. It takes 7 steps and about 60 minutes.

Level
Intermediate
Time
About 60 min
Parts
13

Parts list

Tick what you already own. It saves to My Garage, so “Build with what I have” knows.

Wiring

FromToWhy
9 V battery plusTest button, then the supply railPower only while testing
1 MΩ resistorRail to the sense node and finger padSeries resistor
Strap cordSense node through your body to circuit groundStrap under test
Reference ladder6.7 kΩ (4.7k plus 2k), then 30 kΩ, then 30 kΩ (three 10 kΩ each) from rail to groundTwo limits
Upper tap (8.1 V)LM393 pin 5High limit
Lower tap (4.1 V)LM393 pin 2Low limit
Sense nodeLM393 pins 3 and 6Reading
LM393 pins 1 and 71 kΩ to rail, green LED through 330 Ω to groundGood indicator
Red LEDCathode to pins 1 and 7, anode through 1 kΩ to the railFail indicator

No code needed

A wrist strap should have about 1 MΩ in the cord, so static drains slowly and safely, and not 0 Ω, which would be a shock risk, or an open circuit, which gives no protection. This tester uses a 9 V battery and a 1 MΩ series resistor, so the current through your body is only about 9 microamps, far below what you can feel. The sense node sits at 9 V times the strap's resistance over the sum of that and 1 MΩ: a 1 MΩ strap reads about 4.5 V; a 10 MΩ strap about 8.2 V; an open strap 9 V; and a shorted one 0 V. The LM393 pair forms a window comparator that releases its open-collector outputs only when the node is between the lower limit near 4.1 V, about 0.8 MΩ, and the upper limit near 8.1 V, about 9 MΩ, so the green LED lights only for a good strap, and the red LED lights otherwise. Press the button while touching the metal pad with the strap on, and test daily before you work on electronics. Keep the tester battery-only and never connect it to mains or to mains earth.

Test checklist

What you should see at each check. If a reading is far off, stop and use the troubleshooting list.

CheckExpected
1 MΩ across the testGreen
Open circuitRed
ShortedRed
A good strap on your wristGreen

If it does not work

Always red

Check the ladder voltages and the comparator pins.

Always green

Check the red LED wiring.

Dim LEDs

Check the pull-up and the series resistors.

Strap reads open

Clean the contacts and the wrist plate.

Still stuck? Find the fault step by step with your multimeter →

Ask Lark AI

Common questions

What parts do I need for the ESD wrist strap tester?

Anti-static wrist strap, LM393 Comparator, Resistor 1 kΩ × 2, Resistor 1 MΩ × 2, LED 5 mm green, LED 5 mm red, Resistor 330 Ω × 2, Tactile push button 6 mm, 9 V battery, 9 V battery snap with DC jack, Resistor 10 kΩ × 6, Resistor 4.7 kΩ and Resistor 2 kΩ.

How long does the ESD wrist strap tester take to build?

About 60 minutes for a intermediate maker, in 7 steps.

How do I know the ESD wrist strap tester works?

1 MΩ across the test: Green. Open circuit: Red. Shorted: Red.

Always red: what should I check?

Check the ladder voltages and the comparator pins.

Always green: what should I check?

Check the red LED wiring.

Dim LEDs: what should I check?

Check the pull-up and the series resistors.

Strap reads open: what should I check?

Clean the contacts and the wrist plate.