Lab / Virtual lab / Diodes and power supplies
7805 regulator: dropout and line regulation
Find the input voltage where a 7805 starts regulating, its line regulation and the heat it must get rid of.
Circuit
Updates as you change valuesA 7805 with 0.33 µF and 0.1 µF capacitors, a variable DC input and a load resistor; read the output.
Controls
Changing any setting except input voltage starts a new set of readings.
Meters
Output5 V
Regulator heat0.2 W
Graph
0 readingsYour graph appears here
Take readings, or press Auto sweep to log a full set.
your readings
Theory
- VO = 5 V once Vin ≥ VO + dropout (about 2 V for a 7805)
- Line regulation = ΔVO / ΔVin (datasheet: a few mV per volt)
- Heat PD = (Vin − VO) × IL
- Junction temperature TJ = TA + PD × θJA (θJA ≈ 65 °C/W for a bare TO-220)
- Keep TJ under 125 °C; add a heatsink above about 1 W
Worked out for your values
- Load current
- 50.04 mA
- Regulates from Vin
- 7 V
- Heat in the regulator
- 200 mW
- Junction temp (25 °C room, no heatsink)
- 38 °C
- Efficiency
- 56 %
Your result
Worked out from your readings and compared with theory.
Input where VO reaches 4.95 V (dropout point)
Take readings between 5 V and 8 V input.
Line regulation
Take two or more readings above 8 V.
Sources of error
- Output varies ±4 % between parts (4.8 V to 5.2 V)
- Thermal shutdown at high input and load
- Meter resolution: line regulation needs mV readings
More in Diodes and power supplies