Lab / Virtual lab / Diodes and power supplies

Rectifier with filter capacitor

Measure the ripple on a rectified supply and see how the filter capacitor reduces it.

Diodes and power suppliesSimulatedFull experiment write-up →

Circuit

Updates as you change values
9 V pkBridgeBridgeC470 µFRL470 Ω

A 9 V peak, 50 Hz source into a half-wave or bridge rectifier with a reservoir capacitor and a load resistor.

Controls

Changing any setting except filter capacitor starts a new set of readings.

Meters

DC output7.43 V
Ripple (peak-to-peak)0.344 V

Graph

0 readings

Your graph appears here

Take readings, or press Auto sweep to log a full set.

your readings

Theory

  • Peak output Vp = Vm − n VD (n = 1 half-wave, 2 for a bridge)
  • Ripple Vr ≈ IDC / (f C), with f = 50 Hz half-wave, 100 Hz full-wave
  • VDC ≈ Vp − Vr / 2
  • Ripple factor r = Vr / (2√3 VDC)
  • Without a capacitor r = 1.21 (half-wave) and 0.48 (full-wave)

Worked out for your values

Peak output
7.6 V
Ripple frequency
100 Hz
Ripple (p-p)
344 mV
DC output
7.428 V
Ripple factor
0.013
Diode PIV
9 V

Your result

Worked out from your readings and compared with theory.

Vr × C (ripple constant)

Take two or more readings where the ripple is under half the peak.

Sources of error

  • Capacitor ESR adds a step to the ripple
  • Transformer winding resistance lowers the peak
  • The approximation assumes small ripple; it overestimates at low C