Lab / Virtual lab / Diodes and power supplies
Rectifier with filter capacitor
Measure the ripple on a rectified supply and see how the filter capacitor reduces it.
Circuit
Updates as you change valuesA 9 V peak, 50 Hz source into a half-wave or bridge rectifier with a reservoir capacitor and a load resistor.
Controls
Changing any setting except filter capacitor starts a new set of readings.
Meters
DC output7.43 V
Ripple (peak-to-peak)0.344 V
Graph
0 readingsYour graph appears here
Take readings, or press Auto sweep to log a full set.
your readings
Theory
- Peak output Vp = Vm − n VD (n = 1 half-wave, 2 for a bridge)
- Ripple Vr ≈ IDC / (f C), with f = 50 Hz half-wave, 100 Hz full-wave
- VDC ≈ Vp − Vr / 2
- Ripple factor r = Vr / (2√3 VDC)
- Without a capacitor r = 1.21 (half-wave) and 0.48 (full-wave)
Worked out for your values
- Peak output
- 7.6 V
- Ripple frequency
- 100 Hz
- Ripple (p-p)
- 344 mV
- DC output
- 7.428 V
- Ripple factor
- 0.013
- Diode PIV
- 9 V
Your result
Worked out from your readings and compared with theory.
Vr × C (ripple constant)
Take two or more readings where the ripple is under half the peak.
Sources of error
- Capacitor ESR adds a step to the ripple
- Transformer winding resistance lowers the peak
- The approximation assumes small ripple; it overestimates at low C
More in Diodes and power supplies