Lab / Virtual lab / DC circuits

Loaded voltage divider

See how a load resistor pulls the output of a divider below its no-load value.

DC circuitsSimulated

Circuit

Updates as you change values
10 VR1 10 kΩR210 kΩRL10 kΩV

A 10 V supply across R1 and R2 in series, with a load resistor across R2; read the output voltage.

Controls

Changing any setting except load starts a new set of readings.

Meters

Output3.33 V

Graph

0 readings

Your graph appears here

Take readings, or press Auto sweep to log a full set.

your readings

Theory

  • No load: VO = V R2 / (R1 + R2)
  • Loaded: VO = V (R2 ‖ RL) / (R1 + R2 ‖ RL)
  • Thevenin view: VTh = no-load VO, RTh = R1 ‖ R2
  • Keep RL ≥ 10 × RTh to stay within about 10 % of VTh

Worked out for your values

No-load output VTh
5 V
RTh = R1 ‖ R2
5 kΩ
Output now
3.333 V
Drop from no-load
33.3 %

Your result

Worked out from your readings and compared with theory.

VTh from 1/VO against 1/RL

Take two or more readings at different loads.

RTh from the same line

Take two or more readings at different loads.

Sources of error

  • Resistor tolerance shifts the no-load value
  • The voltmeter is itself a load (10 MΩ DMM, much less for an analogue meter)
  • Supply sag under load