Lab / Virtual lab / Diodes and power supplies
Diode clamper
Show that a clamper shifts a signal up or down without changing its shape, and measure the DC level it adds.
Diodes and power suppliesSimulated
Circuit
Updates as you change valuesA 5 V peak sine through a capacitor into a diode to ground, with a bias battery; read the negative and positive peaks of the output.
Controls
Changing any setting except input peak voltage starts a new set of readings.
Meters
Output negative peak-0.65 V
Output positive peak3.35 V
Graph
0 readingsYour graph appears here
Take readings, or press Auto sweep to log a full set.
your readings
Theory
- The diode conducts on the negative peaks and charges the capacitor to VC = VP − VD + VB
- Output = input + VC, so the whole waveform is shifted up
- Negative peak is clamped to VB − VD (about VB − 0.65 V)
- Positive peak = VB − VD + 2 VP; the peak-to-peak swing stays 2 VP
- Time constant R C must be much longer than the signal period or the level droops
Worked out for your values
- Clamped bottom level
- -650 mV
- Capacitor charge VC
- 1.35 V
- Output positive peak
- 3.35 V
- Peak-to-peak swing
- 4 V
Your result
Worked out from your readings and compared with theory.
Peak-to-peak swing kept (slope of positive peak against VP is 2)
Take two or more readings at different input peaks.
Negative peak clamp level
Take a reading.
Sources of error
- Diode forward drop sets the clamp level a little below the bias
- A load resistor discharges the capacitor between peaks, so the level droops
- Use a long R C compared with the signal period
More in Diodes and power supplies