Newton cooling curve lab
Log a cup of warm water as it cools and fit a cooling curve.
Build it step by step
0 of 8 doneWire the probe
Red to 5V, black to GND, yellow to D2 with a 4.7 kilohm pull-up.
Wire the display and button
I2C on A4 and A5, button on D3 to GND.
Upload the sketch
The display reads the room temperature in air.
Warm some water
Around 55 degrees, not boiling.
Put the probe in the cup
Then press the button.
Leave it for 20 minutes
The display shows the temperature and the fitted k.
Copy the CSV from the serial monitor
Plot temperature against time.
Repeat with a lid
Compare the value of k.
How do you build a newton cooling curve lab?
Log a cup of warm water as it cools and fit a cooling curve. You need Arduino Uno R3, DS18B20 waterproof probe, Resistor 4.7 kΩ, SSD1306 OLED Display, Tactile push button 6 mm and Breadboard 830 Tie Points. It takes 8 steps and about 150 minutes.
- Level
- Beginner
- Time
- About 150 min
- Parts
- 6
Parts list
- Development BoardsBuyArduino Uno R3 × 1
- SensorsBuy
- PassivesBuyResistor 4.7 kΩ × 1
- DisplaysBuy
- SwitchesBuy
- PrototypingBuy
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| Probe red wire | Uno 5V | Power |
| Probe black wire | Uno GND | Ground |
| Probe yellow wire | Uno D2 | Data line |
| 4.7 kilohm | Between D2 and 5V | Pull-up for the data line |
| OLED SDA and SCL | Uno A4 and A5 | I2C, address 0x3C |
| Button | Uno D3 to GND | Start logging |
Code
Newton's law of cooling says a warm object loses heat at a rate proportional to how much warmer it is than the room, so its temperature difference falls off exponentially: T minus room equals A times e to the power of minus k t. Taking the natural logarithm of the difference turns that curve into a straight line whose slope is minus k, so the sketch fits a straight line to the logged values and shows k, the cooling rate per minute. First it measures the room temperature with the probe in air, then you put the probe in a cup of warm water and press the button. Use water around 50 to 60 degrees, not boiling, and handle the cup with care; get an adult to help with hot water. The sensor logs one reading every 30 seconds for up to half an hour. Compare k for an open cup, a cup with a lid and a cup wrapped in a towel, which should show a smaller k. The waterproof probe is accurate to about half a degree, so use the same probe for every run.
Runs on a virtual Arduino Uno in your browser, with sliders for the sensors. Happy with it? Verify and upload to your real board from the same page (Chrome or Edge on a computer).
#include <OneWire.h>
#include <DallasTemperature.h>
#include <Wire.h>
#include <Adafruit_GFX.h>
#include <Adafruit_SSD1306.h>
OneWire bus(2);
DallasTemperature probe(&bus);
Adafruit_SSD1306 oled(128, 64, &Wire, -1);
const int START_BTN = 3;
const unsigned long INTERVAL_MS = 30000; // one reading every 30 seconds
const int MAXN = 60; // up to 30 minutes
float roomC = 0;
float tMin[MAXN], tC[MAXN];
int n = 0;
bool logging = false;
unsigned long lastSample = 0, t0 = 0;
float readC() { probe.requestTemperatures(); return probe.getTempCByIndex(0); }
void show(const char* a, const char* b = "") {
oled.clearDisplay(); oled.setCursor(0, 0);
oled.println(a); oled.println(b); oled.display();
}
// Fit ln(T - room) = ln(A) - k t by least squares, k in 1/minute
float fitK() {
float sx = 0, sy = 0, sxx = 0, sxy = 0; int m = 0;
for (int i = 0; i < n; i++) {
float d = tC[i] - roomC;
if (d < 1.0) continue;
float x = tMin[i], y = log(d);
sx += x; sy += y; sxx += x * x; sxy += x * y; m++;
}
if (m < 4) return 0;
return -((m * sxy - sx * sy) / (m * sxx - sx * sx));
}
void setup() {
Serial.begin(9600);
pinMode(START_BTN, INPUT_PULLUP);
probe.begin();
oled.begin(SSD1306_SWITCHCAPVCC, 0x3C);
oled.setTextColor(SSD1306_WHITE); oled.setTextSize(1);
show("Probe in air...", "reading room temp");
float sum = 0;
for (int i = 0; i < 5; i++) { sum += readC(); delay(1000); }
roomC = sum / 5;
char buf[24]; dtostrf(roomC, 4, 1, buf);
show("Room temp C", buf);
Serial.print("# room C "); Serial.println(roomC, 2);
delay(2000);
show("Put probe in warm", "water, press button");
Serial.println("minutes,celsius");
}
void loop() {
if (!logging && digitalRead(START_BTN) == LOW) {
logging = true; t0 = millis(); lastSample = 0; n = 0; delay(300);
}
if (logging && (n == 0 || millis() - lastSample >= INTERVAL_MS) && n < MAXN) {
lastSample = millis();
float c = readC();
float minutes = (millis() - t0) / 60000.0;
tMin[n] = minutes; tC[n] = c; n++;
Serial.print(minutes, 2); Serial.print(','); Serial.println(c, 2);
char line1[24], line2[24];
dtostrf(c, 4, 1, line1);
float k = fitK();
dtostrf(k, 5, 3, line2);
oled.clearDisplay(); oled.setCursor(0, 0);
oled.print("T "); oled.print(line1); oled.println(" C");
oled.print("k "); oled.print(line2); oled.println(" /min");
oled.print("n "); oled.println(n);
oled.display();
}
}Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| Probe in air | Room temperature near 20 to 30 C |
| Probe in warm water | Starts near 55 C |
| After 10 minutes | Several degrees lower |
| Lidded cup | Smaller k than an open cup |
| Fit with fewer than 4 points | k shows zero |
If it does not work
Reads -127
The probe is not wired or the pull-up is missing.
Reads 85
A power-on default, check the 5V wire and the pull-up.
k looks negative
Room temperature was wrong, restart in air.
Display blank
Check I2C address 0x3C.
Curve is noisy
Keep the probe still and out of draughts.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the newton cooling curve lab?
Arduino Uno R3, DS18B20 waterproof probe, Resistor 4.7 kΩ, SSD1306 OLED Display, Tactile push button 6 mm and Breadboard 830 Tie Points.
How long does the newton cooling curve lab take to build?
About 150 minutes for a beginner maker, in 8 steps.
How do I know the newton cooling curve lab works?
Probe in air: Room temperature near 20 to 30 C. Probe in warm water: Starts near 55 C. After 10 minutes: Several degrees lower.
Reads -127: what should I check?
The probe is not wired or the pull-up is missing.
Reads 85: what should I check?
A power-on default, check the 5V wire and the pull-up.
k looks negative: what should I check?
Room temperature was wrong, restart in air.
Display blank: what should I check?
Check I2C address 0x3C.