Fault finder: Newton cooling curve lab
13 checks for this build on the Uno. Work from the top: power first, then each part, then the code.
0 of 13 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 13
Uno supply pin
Plug the Uno into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Reads -127: what should I check?
The probe is not wired or the pull-up is missing.
Reads 85: what should I check?
A power-on default, check the 5V wire and the pull-up.
k looks negative: what should I check?
Room temperature was wrong, restart in air.
Display blank: what should I check?
Check I2C address 0x3C.
Curve is noisy: what should I check?
Keep the probe still and out of draughts.