Projects / Eight-point soil moisture map

Eight-point soil moisture map

Intermediate2.5 hGuided buildReviewed

Build it step by step

0 of 7 done
  1. NANOMULTI

    Wire the multiplexer

    Connect S0 to S3, SIG, power and enable.

  2. NANOCD74HC40

    Test one sensor

    Print raw values for channel 0.

  3. NANOCD74HC40

    Wire all eight

    Connect each AOUT to its channel and the sensor power.

  4. NANO

    Calibrate each sensor

    Note the dry air and water readings with CALIBRATE true.

  5. NANO

    Enter the numbers

    Fill the DRY and WET arrays.

  6. NANO

    Turn calibration off

    Show percentages on the display.

  7. NANO

    Install

    Seal the boards and place one in each bed.

In short

How do you build an eight-point soil moisture map?

Eight capacitive soil sensors through a 16-channel multiplexer show which beds in a garden are dry on one screen. You need Arduino Nano, CD74HC4067 16-channel mux module, Capacitive Soil Moisture Module × 8, 20x4 LCD with I2C backpack and Multi-core shielded cable 4-core. It takes 7 steps and about 150 minutes.

Level
Intermediate
Time
About 150 min
Parts
5

Parts list

Tick what you already own. It saves to My Garage, so “Build with what I have” knows.

Wiring

FromToWhy
Mux module VCCNano 5VPower
Mux module GNDNano GNDGround
Mux module ENNano GNDEnabled
Mux module S0 to S3Nano D2, D3, D4, D5Channel address bits
Mux module SIGNano A0Selected sensor signal
Sensors 1 to 8 AOUTMux channels C0 to C7One sensor per channel
Sensor VCC and GND (all)Nano 5V and GNDSensor power
LCD 20x4 I2C SDA and SCLNano A4 and A5Display
LCD VCC and GNDNano 5V and GNDPower

Code

Capacitive sensors read lower when wetter, so the percentage maps the dry reading to 0 and the wet reading to 100. Every sensor differs, so calibrate each one: with CALIBRATE set to true, hold each sensor in dry air and note the number, then stand the sensing part (not the electronics) in a glass of water up to the line and note the number again, and enter both in the arrays. Seal the top of each sensor board with epoxy or hot glue so water cannot get to the electronics, and use shielded cable for long runs. The display marks beds below 30 percent with an exclamation mark. Note how many hours each bed takes to dry after watering, which tells you the right watering interval. Arduino IDE, board "Arduino Nano" (processor ATmega328P, or ATmega328P (Old Bootloader) for clones).

Runs on a virtual Arduino Nano in your browser, with sliders for the sensors. Happy with it? Verify and upload to your real board from the same page (Chrome or Edge on a computer).

// Library: LiquidCrystal_I2C. Eight capacitive soil sensors on a 16-channel multiplexer.
#include <Wire.h>
#include <LiquidCrystal_I2C.h>

LiquidCrystal_I2C lcd(0x27, 20, 4);
const byte S[4] = {2, 3, 4, 5};
const byte SIG = A0;
const byte N = 8;
int DRY[N] = {600, 600, 600, 600, 600, 600, 600, 600};    // reading in dry air, set per sensor
int WET[N] = {300, 300, 300, 300, 300, 300, 300, 300};    // reading in water, set per sensor
const bool CALIBRATE = false;                             // true: print raw values only

int readSensor(byte ch) {
  for (byte i = 0; i < 4; i++) digitalWrite(S[i], (ch >> i) & 1);
  delayMicroseconds(200);
  analogRead(SIG);                 // discard the first reading after switching
  long sum = 0;
  for (byte i = 0; i < 8; i++) sum += analogRead(SIG);
  return sum / 8;
}

void setup() {
  for (byte i = 0; i < 4; i++) pinMode(S[i], OUTPUT);
  Serial.begin(9600);
  lcd.init(); lcd.backlight();
}

void loop() {
  for (byte ch = 0; ch < N; ch++) {
    int raw = readSensor(ch);
    int pct = constrain(map(raw, DRY[ch], WET[ch], 0, 100), 0, 100);
    if (CALIBRATE) { Serial.print(raw); Serial.print("\t"); continue; }
    byte row = ch / 2, col = (ch % 2) * 10;
    lcd.setCursor(col, row);
    char b[11];
    sprintf(b, "%d:%3d%%%s ", ch + 1, pct, pct < 30 ? "!" : " ");   // ! marks a dry bed
    lcd.print(b);
  }
  if (CALIBRATE) Serial.println();
  delay(2000);
}

Test checklist

What you should see at each check. If a reading is far off, stop and use the troubleshooting list.

CheckExpected
Dry air0 percent
Sensor in water to the line100 percent
Watered bedPercentage rises within minutes
Dry bedExclamation mark below 30 percent

If it does not work

All sensors show the same

Check the address wires S0 to S3.

Readings jump

Add a short delay or more averaging and check the 5 V supply.

A sensor reads zero

Check its wiring and that the channel is the one you think.

LCD blank

Try address 0x3F.

Still stuck? Find the fault step by step with your multimeter →

Ask Lark AI

Common questions

What parts do I need for the eight-point soil moisture map?

Arduino Nano, CD74HC4067 16-channel mux module, Capacitive Soil Moisture Module × 8, 20x4 LCD with I2C backpack and Multi-core shielded cable 4-core.

How long does the eight-point soil moisture map take to build?

About 150 minutes for a intermediate maker, in 7 steps.

How do I know the eight-point soil moisture map works?

Dry air: 0 percent. Sensor in water to the line: 100 percent. Watered bed: Percentage rises within minutes.

All sensors show the same: what should I check?

Check the address wires S0 to S3.

Readings jump: what should I check?

Add a short delay or more averaging and check the 5 V supply.

A sensor reads zero: what should I check?

Check its wiring and that the channel is the one you think.

LCD blank: what should I check?

Try address 0x3F.