Fault finder: Eight-point soil moisture map
7 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
All sensors show the same: what should I check?
Check the address wires S0 to S3.
Readings jump: what should I check?
Add a short delay or more averaging and check the 5 V supply.
A sensor reads zero: what should I check?
Check its wiring and that the channel is the one you think.
LCD blank: what should I check?
Try address 0x3F.