Projects / LDR response curve lab

LDR response curve lab

Wire an LDR in a divider and read it at several distances from a torch and in the dark. Work out its resistance for each light level and plot the curve to choose the best fixed resistor.

Beginner45 minGuided buildReviewed

Build it step by step

0 of 7 done
  1. 530 lux

    Wire the divider

    9 V plus to the LDR, the LDR to a 10 kilohm resistor, the resistor to 9 V minus.

  2. 530 lux

    Measure in the dark

    Cover the LDR with a box and note Vout.

  3. Measure in room light

    Note Vout and work out the resistance.

  4. Shine the torch from 100, 50, 25, 10 and 5 cm

    Note Vout at each distance.

  5. Swap the fixed resistor to 1 kilohm and then 100 kilohm

    Repeat the readings.

  6. 534 lux

    Work out the LDR resistance each time

    Use Rldr = R x (9 minus Vout) divided by Vout.

  7. Plot all three curves

    See which resistor gives the widest voltage swing.

In short

How do you build an LDR response curve lab?

Wire an LDR in a divider and read it at several distances from a torch and in the dark. Work out its resistance for each light level and plot the curve to choose the best fixed resistor. You need LDR Photoresistor, Resistor 1 kΩ, Resistor 10 kΩ, Resistor 100 kΩ, Digital multimeter, 9 V battery, 9 V battery snap with DC jack, Breadboard 830 Tie Points and Jumper wires male to male (40 pcs, 20 cm). It takes 7 steps and about 45 minutes.

Level
Beginner
Time
About 45 min
Parts
9

Parts list

Tick what you already own. It saves to My Garage, so “Build with what I have” knows.

Wiring

FromToWhy
Battery plus (red lead)LDR leg 1Supply to the top of the divider
LDR leg 2Fixed resistor leg 1 and the meter red probeThe divider output
Fixed resistor leg 2Battery minus (black lead) and the meter black probeGround
Meter dialDC volts, 20 V rangeReads the voltage across the fixed resistor

No code needed

No code. The LDR and the fixed resistor share the 9 V of the battery, and the meter reads the voltage across the fixed resistor. The fixed resistor's voltage is Vout = 9 x R / (R + Rldr), so the LDR's resistance is Rldr = R x (9 minus Vout) divided by Vout. In a dark room an LDR can be about a megohm, in normal room light around 10 to 50 kilohms and close to a phone torch a few kilohms or less, so its resistance changes by hundreds of times. Plot the resistance against the light level on a log scale and you will see roughly a straight line, which is why an LDR is good at telling light from dark but poor at giving exact numbers. The best fixed resistor is close to the LDR's resistance in the middle of the range you care about, which gives the widest swing of voltage. Do not stare into a torch at close range.

Test checklist

What you should see at each check. If a reading is far off, stop and use the troubleshooting list.

CheckExpected
Dark with 10 kilohmsVout under 0.5 V
Room light with 10 kilohmsAbout 1 to 5 V
Torch at 5 cmAbout 6 to 8 V
Same readings with 100 kilohmsLarger voltages in the dark, saturates in bright light
Same readings with 1 kilohmSmall voltages at all but the brightest light

If it does not work

Vout never changes

Check the LDR is in the divider and the meter is across the fixed resistor.

Readings jump about

Mains lights flicker, try daylight or a steady torch.

Numbers differ a lot from these

LDRs vary widely, so use your own curve.

Resistance works out negative

You have swapped Vout, so read across the fixed resistor.

LDR slow to settle

Wait a few seconds after changing the light.

Still stuck? Find the fault step by step with your multimeter →

Ask Lark AI

Common questions

What parts do I need for the LDR response curve lab?

LDR Photoresistor, Resistor 1 kΩ, Resistor 10 kΩ, Resistor 100 kΩ, Digital multimeter, 9 V battery, 9 V battery snap with DC jack, Breadboard 830 Tie Points and Jumper wires male to male (40 pcs, 20 cm).

How long does the LDR response curve lab take to build?

About 45 minutes for a beginner maker, in 7 steps.

How do I know the LDR response curve lab works?

Dark with 10 kilohms: Vout under 0.5 V. Room light with 10 kilohms: About 1 to 5 V. Torch at 5 cm: About 6 to 8 V.

Vout never changes: what should I check?

Check the LDR is in the divider and the meter is across the fixed resistor.

Readings jump about: what should I check?

Mains lights flicker, try daylight or a steady torch.

Numbers differ a lot from these: what should I check?

LDRs vary widely, so use your own curve.

Resistance works out negative: what should I check?

You have swapped Vout, so read across the fixed resistor.