Hydroponic nutrient and pH doser
Build it step by step
0 of 7 doneCalibrate pH
Use buffers 4 and 7.
Calibrate TDS
Use a known standard solution.
Test the pumps
Find the ml delivered per second.
Write the dose logic
Dose, wait and read again.
Add the daily limit
Stop at 12 doses.
Add the display
Show pH, TDS and the last dose.
Run on a bucket
Test with water before using nutrients.
How do you build a hydroponic nutrient and pH doser?
Peristaltic pumps add nutrient or pH-down solution in small doses to keep a hydroponic tank within the TDS and pH targets. You need ESP32 DevKit V1, TDS sensor module, pH sensor kit (analog), DS18B20 waterproof probe, Resistor 4.7 kΩ, Peristaltic pump 12 V × 2, L298N Dual H-Bridge Module, 12 V 2 A DC adapter and SSD1306 OLED Display. It takes 7 steps and about 300 minutes.
- Level
- Advanced
- Time
- About 300 min
- Parts
- 9
Wiring
| From | To | Why |
|---|---|---|
| TDS sensor signal | ESP32 GPIO34 | Analog in |
| pH board output | ESP32 GPIO35 | Analog in |
| DS18B20 data | ESP32 GPIO4, with 4.7 kΩ to 3V3 | Water temperature |
| L298N IN1 and IN2 | ESP32 GPIO25 and GPIO26 | pH-down pump |
| L298N IN3 and IN4 | ESP32 GPIO27 and GPIO14 | Nutrient pump |
| Pumps | L298N OUT1 and OUT3 | Dosing |
| 12 V adapter | L298N supply | Power (fuse 2 A) |
| OLED SDA and SCL | ESP32 GPIO21 and GPIO22 | Display |
Code
Dosing is slow chemistry: add a little, wait for the water to circulate, then read again, because reading right after a dose makes the controller overshoot. Calibrate the pH probe with fresh pH 4 and pH 7 buffer solutions and the TDS probe with a known standard, then replace the two simple conversion lines in the sketch. The daily maximum stops a stuck probe from pumping acid into the tank all night. Keep nutrients, acid and the electronics apart, put the pump tubing in a tray, wear gloves and eye protection when handling concentrated pH-down, and keep it away from children and pets. Arduino IDE with the ESP32 boards package 2.0.x, board "ESP32 Dev Module". This is a hobby controller for leafy greens and herbs; for a commercial crop keep checking by hand.
Runs on a virtual ESP32 Dev Module in your browser, with sliders for the sensors. Happy with it? Verify and upload to your real board from the same page (Chrome or Edge on a computer).
// Doser: dose in small steps, then wait for the water to mix. Board: ESP32 Dev Module.
const int PH_PIN = 34, TDS_PIN = 35;
const int PUMP_PH = 25, PUMP_NUT = 27;
const float PH_MAX = 6.3, TDS_MIN = 700; // set from your crop guide
const unsigned long MIX_WAIT = 15UL * 60UL * 1000UL;
unsigned long lastDose = 0;
int dosesToday = 0;
float readPh() { return 7.0 + (2.5 - analogRead(PH_PIN) * 3.3 / 4095.0) / 0.18; } // replace with your calibration
float readTds() { return analogRead(TDS_PIN) * 3.3 / 4095.0 * 500.0; } // replace with your calibration
void dose(int pin, unsigned long ms) {
digitalWrite(pin, HIGH); delay(ms); digitalWrite(pin, LOW);
lastDose = millis(); dosesToday++;
}
void setup() {
pinMode(PUMP_PH, OUTPUT); pinMode(PUMP_NUT, OUTPUT);
pinMode(26, OUTPUT); pinMode(14, OUTPUT); digitalWrite(26, LOW); digitalWrite(14, LOW);
Serial.begin(115200);
}
void loop() {
float ph = readPh(), tds = readTds();
Serial.printf("pH %.2f TDS %.0f doses %d\n", ph, tds, dosesToday);
if (millis() - lastDose > MIX_WAIT && dosesToday < 12) { // daily maximum of 12 doses
if (ph > PH_MAX) dose(PUMP_PH, 2000);
else if (tds < TDS_MIN) dose(PUMP_NUT, 2000);
}
delay(300000); // read every 5 minutes
}What the serial monitor should show
Open the serial monitor at the baud rate in the code. This is what our simulator prints for a virtual ESP32 Dev Module with its sensors at their default values. Your numbers will follow your real readings, but the format should match.
pH 11.72 TDS 826 doses 0
Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| pH too high | A short pH-down dose |
| TDS too low | A short nutrient dose |
| Right after a dose | No second dose for 15 minutes |
| Probe unplugged | Daily maximum stops dosing |
If it does not work
pH reading jumps
Keep the probe wet and away from pump motors.
Pump delivers little
Prime the tube and check the tube is not kinked.
Overshoots
Shorten the dose or lengthen the wait.
Readings drift
Recalibrate and clean the probes.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the hydroponic nutrient and pH doser?
ESP32 DevKit V1, TDS sensor module, pH sensor kit (analog), DS18B20 waterproof probe, Resistor 4.7 kΩ, Peristaltic pump 12 V × 2, L298N Dual H-Bridge Module, 12 V 2 A DC adapter and SSD1306 OLED Display.
How long does the hydroponic nutrient and pH doser take to build?
About 300 minutes for a advanced maker, in 7 steps.
How do I know the hydroponic nutrient and pH doser works?
pH too high: A short pH-down dose. TDS too low: A short nutrient dose. Right after a dose: No second dose for 15 minutes.
pH reading jumps: what should I check?
Keep the probe wet and away from pump motors.
Pump delivers little: what should I check?
Prime the tube and check the tube is not kinked.
Overshoots: what should I check?
Shorten the dose or lengthen the wait.
Readings drift: what should I check?
Recalibrate and clean the probes.