Power Budgets and Thermal Design

ReviewedAdvanced ProAbout 6 min
LM2596
In short

Power Budgets and Thermal Design: the short answer

A power budget lists everything that draws current from each supply rail: the peak current, the average current and how long each lasts. Add the peaks to size the supply, regulators, connectors and wires, and add the averages to estimate battery life and heat.

Level
Advanced
Time
About 6 min
Topic
Power
You will learn to

Build a power budget for a whole project and check that every part stays below its temperature limit.

Before this: Linear Regulators and Heat, Buck and Boost Converters

A power budget lists everything that draws current from each supply rail: the peak current, the average current and how long each lasts. Add the peaks to size the supply, regulators, connectors and wires, and add the averages to estimate battery life and heat. Then add margin: run regulators and supplies at no more than about 70 to 80 % of their rating.

Every part that drops voltage while carrying current makes heat: P = V × I for a regulator or transistor, I² × R for a resistor or MOSFET. The temperature it reaches depends on how easily the heat escapes, given as thermal resistance in °C per watt. The junction temperature is Tj = Ta + P × θ, where Ta is the air temperature around it. A TO-220 regulator with no heatsink has a θJA of roughly 50 to 65 °C/W (check its datasheet); with a heatsink you add θJC (junction to case), the pad or paste, and the heatsink's own rating.

Keep Tj well below the datasheet maximum (often 125 or 150 °C) at the hottest room or enclosure temperature you expect. In India that can be 40 °C or more indoors in summer, and a closed plastic box adds another 10 to 20 °C. If the numbers do not fit, reduce the power (a buck converter instead of a linear regulator), spread it over more parts, or improve the cooling.

Add up every load

A power budget lists each part's current at its supply voltage, in the worst case and in typical use, and then adds the conversion loss. A linear regulator wastes (Vin − Vout) × I as heat; a switching one wastes a smaller share set by its efficiency. Check the supply can give the total current with margin, including start-up peaks from motors and radios.

For battery projects, use the average current over time, including sleep, and divide the usable capacity by it to estimate run time. Allow for the fact that capacity falls in the cold and with high current.

Heat has to go somewhere

Temperature rise is power times thermal resistance. A regulator dropping 7 V at 0.5 A dissipates 3.5 W, and at a thermal resistance of 50 °C per watt that is a 175 °C rise, which is far too much. Reduce the loss with a switching regulator, spread it over several parts, or add a heatsink and airflow.

Use the junction-to-ambient figure on the datasheet only as a guide, since the board's copper area, the enclosure and the air around it change it. Measure the real temperature after a long run in the enclosure.

Margins

Keep parts well below their maximum temperature, because life falls with heat. Check the enclosure in the worst case, such as direct sun, since the air inside can be much hotter than outside.

Common mistakes
  • Budgeting from typical current and ignoring peaks.
  • Dropping a large voltage across a linear regulator and overheating it.
  • Testing the temperature outside the enclosure instead of inside.
Key formulas
Pin = Pout ÷ η
input power
Tj = Ta + P × θJA
junction temperature
Try it: Will the part overheat?

Junction temperature against power

0 °C50 °C100 °C0 W500 mW1 W1.5 WPower49 °C

Each watt raises the junction temperature by θJA degrees. Try a hot enclosure.

Tj = 49 °C

Tj125 °C limitJunction temperature against power. Each watt adds 60 °C. Keep the line under the part's maximum, often 125 °C.

Work it with your own numbers: Power budget · Junction temperature

Advanced lesson · Pro plan

Practise this lesson with Pro

The explanation above is free for everyone. The practice for Advanced lessons in every domain are part of the Pro plan at ₹999 a month.

With Pro you also get: a worked example, a hands-on task, a 3-question check.

Common questions

What will I learn in "Power Budgets and Thermal Design"?

Build a power budget for a whole project and check that every part stays below its temperature limit.