Lab / Virtual lab / AC and filters
Series RLC resonance
Find the resonant frequency where the current peaks, and the bandwidth and Q.
Circuit
Updates as you change valuesA 1 V sine into a series R, L and C; read the current with a resistor and the CRO.
Controls
Changing any setting except frequency starts a new set of readings.
Meters
Current2.81 mA
Phase73.7 °
Graph
0 readingsYour graph appears here
Take readings, or press Auto sweep to log a full set.
your readings
Theory
- f0 = 1 / (2π √(LC)): there XL = XC and Z = R
- Z = √(R² + (XL − XC)²), XL = 2πfL, XC = 1 / (2πfC)
- Q = (1/R) √(L/C) = 2πf0L / R
- Bandwidth BW = f2 − f1 = f0 / Q = R / (2πL), at I = Imax / √2
- At f0 the voltage across L (and C) is Q times the supply
Worked out for your values
- Resonant f0
- 5.033 kHz
- Quality factor Q
- 3.16
- Bandwidth
- 1.592 kHz
- Peak current V/R
- 10 mA
- XL now
- 188.5 Ω
- XC now
- 530.5 Ω
- Voltage across L at f0
- 3.162 V
Your result
Worked out from your readings and compared with theory.
f0 at the current peak
Take readings on both sides of the peak.
Peak current
Take readings on both sides of the peak.
Bandwidth f2 − f1 (half-power points)
Take readings past both half-power points (0.707 × peak).
Sources of error
- Coil winding resistance adds to R, lowering Q and the peak
- Generator output resistance
- Finding the exact peak on the CRO by eye
More in AC and filters