Lab / Virtual lab / AC and filters

Active first-order filter with gain

Plot the response of an op-amp low-pass or high-pass filter and measure its pass-band gain and cut-off.

AC and filtersSimulatedFull experiment write-up →

Circuit

Updates as you change values
−+VORf 10 kΩR1 10 kΩ1 VRC

An RC section into a non-inverting 741 stage (gain 1 + Rf/R1) on ±12 V; a 1 V sine in, output on the CRO.

Controls

Changing any setting except frequency starts a new set of readings.

Meters

Frequency1000 Hz
Output1.69 V
Gain4.58 dB

Graph

0 readings

Your graph appears here

Take readings, or press Auto sweep to log a full set.

your readings

Theory

  • Pass-band gain AF = 1 + Rf / R1
  • fc = 1 / (2π R C)
  • Low-pass |H| = AF / √(1 + (f/fc)²); high-pass |H| = AF (f/fc) / √(1 + (f/fc)²)
  • −3 dB point where the gain is AF / √2
  • The 741 has a 1 MHz gain-bandwidth, so the stage itself rolls off near 1 MHz / AF

Worked out for your values

Pass-band gain AF
2.0 (6.02 dB)
Cut-off fc
1.592 kHz
Op-amp limit 1 MHz / AF
500 kHz
Frequency now
1 kHz

Your result

Worked out from your readings and compared with theory.

Pass-band gain

Take readings in the pass band.

fc where gain is 3 dB below the pass band

Take readings either side of the cut-off.

Sources of error

  • Op-amp gain-bandwidth limits the high-frequency end
  • Slew rate (0.5 V/µs on a 741) distorts large, fast signals
  • Resistor and capacitor tolerance move fc