Lab / Virtual lab / AC and filters
Active first-order filter with gain
Plot the response of an op-amp low-pass or high-pass filter and measure its pass-band gain and cut-off.
Circuit
Updates as you change valuesAn RC section into a non-inverting 741 stage (gain 1 + Rf/R1) on ±12 V; a 1 V sine in, output on the CRO.
Controls
Changing any setting except frequency starts a new set of readings.
Meters
Frequency1000 Hz
Output1.69 V
Gain4.58 dB
Graph
0 readingsYour graph appears here
Take readings, or press Auto sweep to log a full set.
your readings
Theory
- Pass-band gain AF = 1 + Rf / R1
- fc = 1 / (2π R C)
- Low-pass |H| = AF / √(1 + (f/fc)²); high-pass |H| = AF (f/fc) / √(1 + (f/fc)²)
- −3 dB point where the gain is AF / √2
- The 741 has a 1 MHz gain-bandwidth, so the stage itself rolls off near 1 MHz / AF
Worked out for your values
- Pass-band gain AF
- 2.0 (6.02 dB)
- Cut-off fc
- 1.592 kHz
- Op-amp limit 1 MHz / AF
- 500 kHz
- Frequency now
- 1 kHz
Your result
Worked out from your readings and compared with theory.
Pass-band gain
Take readings in the pass band.
fc where gain is 3 dB below the pass band
Take readings either side of the cut-off.
Sources of error
- Op-amp gain-bandwidth limits the high-frequency end
- Slew rate (0.5 V/µs on a 741) distorts large, fast signals
- Resistor and capacitor tolerance move fc
More in AC and filters