Lab / Virtual lab / AC and filters
RC low-pass and high-pass filters
Plot the gain of an RC filter against frequency and find the cut-off.
Circuit
Updates as you change valuesA 1 V sine from the function generator into an RC filter; read the output on the CRO.
Controls
Changing any setting except frequency starts a new set of readings.
Meters
Frequency1000 Hz
Output0.847 V
Gain-1.45 dB
Phase-32.1 °
Graph
0 readingsYour graph appears here
Take readings, or press Auto sweep to log a full set.
your readings
Theory
- fc = 1 / (2π R C)
- Low-pass |H| = 1 / √(1 + (f/fc)²), phase = −arctan(f/fc)
- High-pass |H| = (f/fc) / √(1 + (f/fc)²), phase = 90° − arctan(f/fc)
- At fc the gain is −3 dB (0.707) and the phase is ∓45°
- Beyond fc the gain falls 20 dB per decade (6 dB per octave)
Worked out for your values
- Cut-off fc
- 1.592 kHz
- Frequency now
- 1 kHz
- Gain now
- -1.45 dB
- Phase now
- -32.1°
- XC at fc (= R)
- 1 kΩ
Your result
Worked out from your readings and compared with theory.
fc where the gain is −3 dB
Take readings either side of the cut-off.
Roll-off far from fc
Take two or more readings above 3 fc.
Sources of error
- Generator output resistance (often 50 Ω or 600 Ω) adds to R
- CRO probe capacitance at high frequency
- Reading peak-to-peak on a thick trace
More in AC and filters