Induction motor health monitor (vibration and current)
Small factories and pump houses run motors until they fail. Watching vibration, current and temperature can warn of bearing wear and overload days before a breakdown.
- Parts
- ₹1,510
- Build
- 14 weeks
- Board
- ESP32
- Objectives
- 5
Block diagram
- ADXL345 accelerometerMeasures vibration
- CT sensorMeasures motor current
- DS18B20Measures body temperature
- ESP32Computes RMS and FFT features
- DashboardShows health and trends
- Cloud dashboardStores readings, plots trends and sends alerts+
Objectives
- To measure vibration velocity RMS and its main frequencies with an FFT.
- To measure motor current and temperature.
- To tell normal, unbalanced and overloaded running apart.
- To report the warning lead time in a test with added imbalance.
- To publish readings over MQTT and show them on a live dashboard with threshold alerts.
Parts and specifications
- ESP32 DevKit V1Dual-core 240 MHz, 520 KB SRAM, Wi-Fi + Bluetooth, 3.3 V logic, 12-bit ADC (use ADC1 pins when Wi-Fi is on)₹450Buy
- SCT-013-030 split-core CT0 to 30 A AC to 0 to 1 V AC (built-in burden), clamp on without breaking the wire₹450Buy
- DS18B20 waterproof probe−55 to 125 °C, ±0.5 °C from −10 to 85 °C, 9 to 12-bit, 1-Wire with 4.7 kΩ pull-up, 750 ms at 12-bit₹120Buy
- 3.5 mm jack, 10 kΩ bias resistors and 10 µF capacitor₹40
- Small 230 V motor or fan on the lab test bench₹0
- Wires and box₹200
Total about ₹1,510 at typical online prices. Tap a part for its pinout and datasheet notes.
Design calculations
Sample at 3200 Hz, 1024 points: bin width 3200 / 1024 = 3.1 Hz, enough to see 1× running speed (about 24 Hz for 1440 RPM) and 2×.
ISO 20816 uses velocity in mm/s. Integrate acceleration in the frequency domain: v = a / (2πf). 0.5 m/s² at 24 Hz gives 3.3 mm/s.
Irms = √(Σ(vi − 1.65)² / N) × (30 A / 1 V). 0.1 V RMS = 3 A.
For a small machine (class I) about 0.7 / 1.8 / 4.5 mm/s separate good, acceptable, unsatisfactory and unacceptable.
Pin map
| Signal | Pin or connection |
|---|---|
| ADXL345 SPI CS / SCK / SDO / SDA | GPIO 5 / 18 / 19 / 23 (SPI for 3200 Hz) |
| SCT-013 output | GPIO 34 via 3.5 mm jack, biased at 1.65 V with 10 kΩ / 10 kΩ and 10 µF |
| DS18B20 | GPIO 4 (4.7 kΩ pull-up) |
Firmware outline
- Every 10 s capture 1024 vibration samples at 3200 Hz and 2000 current samples at 2 kHz.
- Remove the mean, apply a Hann window and run the FFT.
- Compute velocity RMS (10 to 1000 Hz), amplitudes at 1× and 2× speed, current RMS and temperature.
- Classify: imbalance (1× high), misalignment (2× high), overload (current above rating).
- Publish features and the health state to the dashboard.
Test plan
| Test | Expected result |
|---|---|
| Healthy running | Baseline features stored |
| Small weight taped to the fan blade | 1× amplitude rises, imbalance flagged |
| Load increased | Current and temperature rise |
| Clamp CT vs clamp meter | Within 5% |
These rows start your results table when you plan the project.
Viva practice
Say your answer out loud first, then check. The first 2 answers are free; Maker opens all 5.
Make it yours
One or two upgrades for a mini project, two to four for a major one.
Build these first
Datasheets and sources to cite
- Analog Devices ADXL345 datasheet
- YHDC SCT-013 datasheet
- ISO 20816-1 (vibration severity; replaces ISO 10816)
About this project
How much does the induction motor health monitor (vibration and current) project cost?
About ₹1,510 for the parts in the base list: ESP32 DevKit V1, ADXL345 accelerometer, SCT-013-030 split-core CT, DS18B20 waterproof probe, 3.5 mm jack, 10 kΩ bias resistors and 10 µF capacitor, Small 230 V motor or fan on the lab test bench, Wires and box.
How long does it take?
About 12 weeks for the base project, built on an ESP32. Each upgrade adds time.
Which branches is it suitable for?
Electrical and Electronics, Instrumentation, Mechanical / Mechatronics, as a major project.
Which pins and design calculations does it use?
ADXL345 SPI CS / SCK / SDO / SDA on GPIO 5 / 18 / 19 / 23 (SPI for 3200 Hz); SCT-013 output on GPIO 34 via 3.5 mm jack, biased at 1.65 V with 10 kΩ / 10 kΩ and 10 µF; DS18B20 on GPIO 4 (4.7 kΩ pull-up). Worked calculations on this page: sampling and fft, velocity rms, current rms, severity zones.
How do I test it?
Healthy running: Baseline features stored. Small weight taped to the fan blade: 1× amplitude rises, imbalance flagged. Load increased: Current and temperature rise. Clamp CT vs clamp meter: Within 5%.
What are the objectives?
To measure vibration velocity RMS and its main frequencies with an FFT. To measure motor current and temperature. To tell normal, unbalanced and overloaded running apart. To report the warning lead time in a test with added imbalance.