Resistor tolerance sorting lab
Measure ten 1 kilohm and ten 10 kilohm resistors with a multimeter, tabulate the readings and see how they spread around their marking. You learn what a five percent tolerance really looks like, and why exact values are rare.
Build it step by step
0 of 7 doneCheck the meter on a known short
The reading should be near zero.
Measure the first resistor
Write the reading down.
Measure all twenty
Keep fingers off the leads.
Work out the average and spread
For each value separately.
Find the biggest error as a percentage
Compare with the band.
Sort into three piles
Close, middle and far.
Measure one resistor five times
See the meter's own steadiness.
How do you build a resistor tolerance sorting lab?
Measure ten 1 kilohm and ten 10 kilohm resistors with a multimeter, tabulate the readings and see how they spread around their marking. You learn what a five percent tolerance really looks like, and why exact values are rare. You need Resistor 1 kΩ × 10, Resistor 10 kΩ × 10, Digital multimeter and Breadboard 830 Tie Points. It takes 7 steps and about 50 minutes.
- Level
- Beginner
- Time
- About 50 min
- Parts
- 4
Parts list
- PassivesBuyResistor 1 kΩ × 10
- PassivesBuyResistor 10 kΩ × 10
- Tools & InstrumentsBuy
- PrototypingBuy
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| Meter red probe | One lead of the resistor | Hold the lead against the probe tip |
| Meter black probe | The other lead of the resistor | Same, but keep your fingers off the metal |
| Meter dial | 2 kilohm range, then 20 kilohm | Use the range just above the value |
No code needed
No code. Take ten resistors marked 1 kilohm and ten marked 10 kilohm, all with the same gold or silver tolerance band. Measure each one on a suitable range of your meter, with the resistor out of any circuit and with your fingers off the metal leads, because your body adds a parallel path that lowers a big reading. Write each reading in a table, then work out the average, the lowest, the highest and the biggest error as a percentage of the marked value. Compare the biggest error with the tolerance band, which is five percent for gold and ten percent for silver. Most resistors fall well inside it, but a few may sit near the edge. Then sort the ten into three small piles, close, middle and far, and think about when you would need a closer match, such as in a divider or a filter. Your own meter also has a small error, so measure one resistor several times and see how steady it reads. A five-band precision resistor makes a good comparison if you have one.
Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| Average of the ten | Close to the marked value |
| Biggest error | Inside the tolerance band |
| Same resistor measured again | Readings agree within a digit or two |
| Fingers on both leads | A high value reads lower |
| Sorted piles | The closest ones go together |
If it does not work
Readings jump around
Press the probes firmly and keep fingers off the leads.
Reading shows OL
Use a higher range.
Reading far from the mark
Check the colour bands, it may be a different value.
Meter reads about 0.2 on a short
Subtract the probe resistance.
All readings similar but off
Your meter may be out, try another.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the resistor tolerance sorting lab?
Resistor 1 kΩ × 10, Resistor 10 kΩ × 10, Digital multimeter and Breadboard 830 Tie Points.
How long does the resistor tolerance sorting lab take to build?
About 50 minutes for a beginner maker, in 7 steps.
How do I know the resistor tolerance sorting lab works?
Average of the ten: Close to the marked value. Biggest error: Inside the tolerance band. Same resistor measured again: Readings agree within a digit or two.
Readings jump around: what should I check?
Press the probes firmly and keep fingers off the leads.
Reading shows OL: what should I check?
Use a higher range.
Reading far from the mark: what should I check?
Check the colour bands, it may be a different value.
Meter reads about 0.2 on a short: what should I check?
Subtract the probe resistance.