Projects / Energy meter data logger

Energy meter data logger

Intermediate4 hGuided buildReviewed

Build it step by step

0 of 7 done
  1. ESP32

    Read the meter's manual

    Address, speed, registers.

  2. ESP32

    Wire A and B

    Low-voltage side only.

  3. ESP32

    Read one register

    Print the voltage.

  4. ESP32

    Check against the display

    Same value.

  5. ESP32

    Read the other values

    Current and energy.

  6. ESP32

    Log to SD with time

    One line a minute.

  7. ESP32

    Plot the load profile

    In a spreadsheet.

In short

How do you build an energy meter data logger?

Read a Modbus energy meter every minute and save kWh, current and power factor to SD and the cloud. You need ESP32 DevKit V1, RS485 to TTL auto-direction module, MicroSD Card Module, SanDisk microSD card 32 GB (A1, Class 10), DS3231 RTC module and 5 V 2 A USB adapter. It takes 7 steps and about 240 minutes.

Level
Intermediate
Time
About 240 min
Parts
6

Parts list

Tick what you already own. It saves to My Garage, so “Build with what I have” knows.

Wiring

FromToWhy
RS485 module RXD (receive) and TXD (transmit)ESP32 GPIO17 (TX2) and GPIO16 (RX2)Serial to the bus (swap if no reply)
RS485 module VCC and GNDESP32 3V3 or 5V (as the module needs) and GNDPower
RS485 A and BMeter A and B terminals (low voltage communication side)Modbus bus
Meter mains terminalsWired by a qualified electrician onlyNot touched by this build
SD module CS, MOSI, MISO, SCKESP32 GPIO5, GPIO23, GPIO19, GPIO18SPI
SD module VCC and GNDESP32 VIN (5 V) and GNDPower
RTC SDA and SCLESP32 GPIO21 and GPIO22I2C

Code

Industrial meters often have a small RS485 port, a two-wire bus that carries Modbus messages: the logger asks for a register by number, and the meter answers with the value. The ESP32 needs the RS485 module because the bus uses different voltage levels from the ESP32's pins, and the auto-direction type switches between sending and listening on its own. The hardest part is not the code but the meter's manual: it lists the slave address, speed, data type and register numbers, and every make is different, so the addresses in the sketch are only examples. Test with one register first and check that the value looks right against the meter's display. The communication terminals are low voltage, but the meter itself is connected to the mains, and its installation must be done by a qualified electrician in an enclosure; never open a live meter. If the bus is long, add a 120 ohm resistor across A and B at the far end, and keep the data wires away from mains cables. A plain Modbus bus is not encrypted or secured, so keep the logger on a private network. Arduino IDE with the ESP32 boards package 2.0.x, board "ESP32 Dev Module".

Runs on a virtual ESP32 Dev Module in your browser, with sliders for the sensors. Happy with it? Verify and upload to your real board from the same page (Chrome or Edge on a computer).

// Modbus RTU data logger: reads a meter's voltage, current and energy every minute and writes a CSV line to the SD card.
// Libraries: ModbusMaster, SD, RTClib. Board: ESP32 Dev Module.
// IMPORTANT: the register addresses below are examples only. Use your own meter's manual for the real addresses, data types and units.
#include <ModbusMaster.h>
#include <SPI.h>
#include <SD.h>
#include <RTClib.h>
ModbusMaster node;
RTC_DS3231 rtc;
const byte METER_ID = 1;
const long BAUD = 9600;                       // the meter's own setting: 9600 8N1 is common
const uint16_t REG_VOLTS = 0x0000;            // example: float, 2 registers
const uint16_t REG_AMPS = 0x0006;             // example
const uint16_t REG_KWH = 0x0156;              // example
unsigned long lastLog = 0;
float readFloat(uint16_t reg, bool &ok) {
  uint8_t r = node.readInputRegisters(reg, 2);
  if (r != node.ku8MBSuccess) { ok = false; return 0; }
  uint32_t raw = ((uint32_t)node.getResponseBuffer(0) << 16) | node.getResponseBuffer(1);   // high word first: check your manual
  float f; memcpy(&f, &raw, 4); return f;
}
void setup() {
  Serial.begin(115200);
  Serial2.begin(BAUD, SERIAL_8N1, 16, 17);
  node.begin(METER_ID, Serial2);
  rtc.begin();
  if (!SD.begin(5)) { Serial.println("SD card error"); while (true) delay(1000); }
  File f = SD.open("/meter.csv", FILE_APPEND);
  if (f) { if (f.size() == 0) f.println("date,time,volts,amps,kwh"); f.close(); }
}
void loop() {
  if (millis() - lastLog >= 60000UL) {
    lastLog = millis();
    bool ok = true;
    float v = readFloat(REG_VOLTS, ok), a = readFloat(REG_AMPS, ok), e = readFloat(REG_KWH, ok);
    DateTime n = rtc.now();
    char line[96];
    if (ok) snprintf(line, sizeof(line), "%04d-%02d-%02d,%02d:%02d:%02d,%.1f,%.3f,%.2f", n.year(), n.month(), n.day(), n.hour(), n.minute(), n.second(), v, a, e);
    else snprintf(line, sizeof(line), "%04d-%02d-%02d,%02d:%02d:%02d,read failed", n.year(), n.month(), n.day(), n.hour(), n.minute(), n.second());
    File f = SD.open("/meter.csv", FILE_APPEND);
    if (f) { f.println(line); f.close(); }
    Serial.println(line);
  }
}

Test checklist

What you should see at each check. If a reading is far off, stop and use the troubleshooting list.

CheckExpected
VoltageMatches the meter's own display
Switch a load onCurrent rises in the log
CSV fileOpens with correct times
Bus unpluggedLines say read failed

If it does not work

No reply

Check A and B are not swapped and the address and speed match.

Strange numbers

Check the word order and the data type.

Random failures

Add termination and keep the cable away from mains wiring.

Still stuck? Find the fault step by step with your multimeter →

Ask Lark AI

Common questions

What parts do I need for the energy meter data logger?

ESP32 DevKit V1, RS485 to TTL auto-direction module, MicroSD Card Module, SanDisk microSD card 32 GB (A1, Class 10), DS3231 RTC module and 5 V 2 A USB adapter.

How long does the energy meter data logger take to build?

About 240 minutes for a intermediate maker, in 7 steps.

How do I know the energy meter data logger works?

Voltage: Matches the meter's own display. Switch a load on: Current rises in the log. CSV file: Opens with correct times.

No reply: what should I check?

Check A and B are not swapped and the address and speed match.

Strange numbers: what should I check?

Check the word order and the data type.

Random failures: what should I check?

Add termination and keep the cable away from mains wiring.