Full-wave rectifier and filter lab
Build it step by step
0 of 7 doneSet the source
Generator to a 50 Hz sine at about 6 V peak with no DC offset.
Build the bridge
Connect the two AC inputs to the generator and the DC outputs to a 1 kΩ load.
Look at the output
The scope shows bumps at 100 Hz, twice the input frequency.
Add 100 µF
Connect it across the load with the correct polarity. The ripple shrinks and the DC level rises.
Replace it with 1000 µF
The output is smoother still.
Measure ripple
Read the peak-to-peak ripple on the scope and compare it with the formula.
Use a lighter and a heavier load
A bigger load current gives more ripple.
How do you build a full-wave rectifier and filter lab?
A safe low-voltage AC source, a bridge rectifier and capacitors show how AC becomes smooth DC. You need Bridge rectifier DB107 (1 A), Electrolytic Capacitor 100 µF, Electrolytic capacitor 1000 µF, Resistor 1 kΩ, Function generator (DDS), USB oscilloscope / handheld scope (DSO138), Breadboard 830 Tie Points and Jumper wires male to male (40 pcs, 20 cm). It takes 7 steps and about 60 minutes.
- Level
- Beginner
- Time
- About 60 min
- Parts
- 8
Wiring
| From | To | Why |
|---|---|---|
| Function generator output | Bridge AC input 1 and AC input 2 | Low-voltage AC (50 Hz sine, 6 V peak, no offset) |
| Bridge + output | Load resistor 1 kΩ, capacitor + | DC side |
| Bridge - output | Load resistor, capacitor - and ground | Return |
| Scope probe | Across the load | Watch the output |
| Scope ground clip | Bridge - output | Reference |
No code needed
No code and no mains. Use only a low-voltage AC source such as a function generator, never wall power. Ripple voltage is roughly load current ÷ (2 × frequency × capacitance). For a 5 mA load at 50 Hz, 100 µF gives about 0.5 V of ripple and 1000 µF about 0.05 V. The bridge drops about 1.4 V.
Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| No capacitor | Bumps at 100 Hz, peaks near 4.6 V |
| 100 µF | Ripple about 0.5 V peak to peak at 5 mA |
| 1000 µF | Ripple about 0.05 V |
| Heavier load | Ripple grows |
If it does not work
Output looks like half-wave
A diode in the bridge is damaged or the source has a DC offset.
Capacitor gets warm or leaks
It is reversed. Turn it round immediately.
Scope reading is odd
The ground clip is on the wrong node. Put it on the bridge negative output.
Generator output collapses
The load is too heavy. Use a higher resistor value.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the full-wave rectifier and filter lab?
Bridge rectifier DB107 (1 A), Electrolytic Capacitor 100 µF, Electrolytic capacitor 1000 µF, Resistor 1 kΩ, Function generator (DDS), USB oscilloscope / handheld scope (DSO138), Breadboard 830 Tie Points and Jumper wires male to male (40 pcs, 20 cm).
How long does the full-wave rectifier and filter lab take to build?
About 60 minutes for a beginner maker, in 7 steps.
How do I know the full-wave rectifier and filter lab works?
No capacitor: Bumps at 100 Hz, peaks near 4.6 V. 100 µF: Ripple about 0.5 V peak to peak at 5 mA. 1000 µF: Ripple about 0.05 V.
Output looks like half-wave: what should I check?
A diode in the bridge is damaged or the source has a DC offset.
Capacitor gets warm or leaks: what should I check?
It is reversed. Turn it round immediately.
Scope reading is odd: what should I check?
The ground clip is on the wrong node. Put it on the bridge negative output.
Generator output collapses: what should I check?
The load is too heavy. Use a higher resistor value.