Projects / Full-wave rectifier and filter lab

Full-wave rectifier and filter lab

Beginner1 hGuided buildReviewed

Build it step by step

0 of 7 done
  1. 4.98V

    Set the source

    Generator to a 50 Hz sine at about 6 V peak with no DC offset.

  2. 4.98V

    Build the bridge

    Connect the two AC inputs to the generator and the DC outputs to a 1 kΩ load.

  3. 4.98V

    Look at the output

    The scope shows bumps at 100 Hz, twice the input frequency.

  4. Add 100 µF

    Connect it across the load with the correct polarity. The ripple shrinks and the DC level rises.

  5. Replace it with 1000 µF

    The output is smoother still.

  6. 4.98V

    Measure ripple

    Read the peak-to-peak ripple on the scope and compare it with the formula.

  7. Use a lighter and a heavier load

    A bigger load current gives more ripple.

In short

How do you build a full-wave rectifier and filter lab?

A safe low-voltage AC source, a bridge rectifier and capacitors show how AC becomes smooth DC. You need Bridge rectifier DB107 (1 A), Electrolytic Capacitor 100 µF, Electrolytic capacitor 1000 µF, Resistor 1 kΩ, Function generator (DDS), USB oscilloscope / handheld scope (DSO138), Breadboard 830 Tie Points and Jumper wires male to male (40 pcs, 20 cm). It takes 7 steps and about 60 minutes.

Level
Beginner
Time
About 60 min
Parts
8
See the electronics first. This build uses AC rectifier. Try an AC rectifier in the circuit builder and watch the voltages and currents before you wire it.

Parts list

Tick what you already own. It saves to My Garage, so “Build with what I have” knows.

Wiring

FromToWhy
Function generator outputBridge AC input 1 and AC input 2Low-voltage AC (50 Hz sine, 6 V peak, no offset)
Bridge + outputLoad resistor 1 kΩ, capacitor +DC side
Bridge - outputLoad resistor, capacitor - and groundReturn
Scope probeAcross the loadWatch the output
Scope ground clipBridge - outputReference

No code needed

No code and no mains. Use only a low-voltage AC source such as a function generator, never wall power. Ripple voltage is roughly load current ÷ (2 × frequency × capacitance). For a 5 mA load at 50 Hz, 100 µF gives about 0.5 V of ripple and 1000 µF about 0.05 V. The bridge drops about 1.4 V.

Test checklist

What you should see at each check. If a reading is far off, stop and use the troubleshooting list.

CheckExpected
No capacitorBumps at 100 Hz, peaks near 4.6 V
100 µFRipple about 0.5 V peak to peak at 5 mA
1000 µFRipple about 0.05 V
Heavier loadRipple grows

If it does not work

Output looks like half-wave

A diode in the bridge is damaged or the source has a DC offset.

Capacitor gets warm or leaks

It is reversed. Turn it round immediately.

Scope reading is odd

The ground clip is on the wrong node. Put it on the bridge negative output.

Generator output collapses

The load is too heavy. Use a higher resistor value.

Still stuck? Find the fault step by step with your multimeter →

Ask Lark AI

Common questions

What parts do I need for the full-wave rectifier and filter lab?

Bridge rectifier DB107 (1 A), Electrolytic Capacitor 100 µF, Electrolytic capacitor 1000 µF, Resistor 1 kΩ, Function generator (DDS), USB oscilloscope / handheld scope (DSO138), Breadboard 830 Tie Points and Jumper wires male to male (40 pcs, 20 cm).

How long does the full-wave rectifier and filter lab take to build?

About 60 minutes for a beginner maker, in 7 steps.

How do I know the full-wave rectifier and filter lab works?

No capacitor: Bumps at 100 Hz, peaks near 4.6 V. 100 µF: Ripple about 0.5 V peak to peak at 5 mA. 1000 µF: Ripple about 0.05 V.

Output looks like half-wave: what should I check?

A diode in the bridge is damaged or the source has a DC offset.

Capacitor gets warm or leaks: what should I check?

It is reversed. Turn it round immediately.

Scope reading is odd: what should I check?

The ground clip is on the wrong node. Put it on the bridge negative output.

Generator output collapses: what should I check?

The load is too heavy. Use a higher resistor value.