6 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 6 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 6

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Output looks like half-wave: what should I check?

A diode in the bridge is damaged or the source has a DC offset.

Capacitor gets warm or leaks: what should I check?

It is reversed. Turn it round immediately.

Scope reading is odd: what should I check?

The ground clip is on the wrong node. Put it on the bridge negative output.

Generator output collapses: what should I check?

The load is too heavy. Use a higher resistor value.