Build it step by step
0 of 7 doneWire the programmer
SWDIO, SWCLK, GND and 3.3V.
Wire the sensor and display
SDA to PB7, SCL to PB6, power at 3.3 V.
Install the libraries
Adafruit BME280, Unified Sensor, SSD1306 and GFX.
Upload the sketch
Readings appear on the display.
Plug in the USB cable and unplug the programmer power
Open the serial monitor at 115200.
Wait a minute
A new line arrives each minute.
Move the sensor a few centimetres from the board
Compare the temperature.
How do you build a blue Pill weather node?
A Blue Pill reads temperature, humidity and pressure from a BME280, shows them on an OLED and sends a line over USB serial every minute. You need STM32 Blue Pill (STM32F103C8T6), ST-Link V2 programmer (clone), BME280 Environmental Sensor, SSD1306 OLED Display and Breadboard 830 Tie Points. It takes 7 steps and about 150 minutes.
- Level
- Intermediate
- Time
- About 150 min
- Parts
- 5
Parts list
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| ST-Link GND | Blue Pill GND | Ground |
| ST-Link SWDIO | Blue Pill DIO | Debug data |
| ST-Link SWCLK | Blue Pill DCLK | Debug clock |
| ST-Link 3.3V | Blue Pill 3.3 pin | Power from the programmer (do not also plug in USB) |
| BME280 VCC and OLED VCC | Blue Pill 3.3 pin | Power at 3.3 V |
| BME280 GND and OLED GND | Blue Pill GND | Common ground |
| BME280 SDA and OLED SDA | Blue Pill PB7 | Shared I2C data |
| BME280 SCL and OLED SCL | Blue Pill PB6 | Shared I2C clock |
| USB cable | Blue Pill USB socket | Serial output (after programming, unplug the ST-Link power wire) |
Code
The BME280 measures temperature, humidity and air pressure and holds factory calibration constants inside, which the library reads once and uses to turn the raw counts into real values. It talks over I2C and shares the bus with the OLED, and it answers at 0x76 or 0x77 depending on how the module is wired, so the sketch tries both. The Blue Pill runs at 3.3 V, which suits the sensor. The board has a USB socket that can act as a serial port, so the same sketch also prints a line each minute that you can read in the serial monitor or log to a file on a computer. Readings are indicative only. A sensor close to the board or in sun reads warm, and humidity is easily thrown off by a breath or a hot component, so mount the module on short wires a few centimetres away from the board and out of direct sun. Pressure falls with height, so a reading means more once you compare it with a local report.
Runs on a virtual STM32 Blue Pill in your browser, with sliders for the sensors. Happy with it? Verify and upload to your real board from the same page (Chrome or Edge on a computer).
#include <Wire.h>
#include <Adafruit_BME280.h>
#include <Adafruit_GFX.h>
#include <Adafruit_SSD1306.h>
Adafruit_SSD1306 oled(128, 64, &Wire, -1);
Adafruit_BME280 bme;
unsigned long lastDraw = 0, lastSend = 0;
bool sentFirst = false;
void setup() {
Serial.begin(115200); // USB serial (CDC)
Wire.begin(); // PB7 SDA, PB6 SCL
if (!oled.begin(SSD1306_SWITCHCAPVCC, 0x3C)) { while (true) {} }
if (!bme.begin(0x76) && !bme.begin(0x77)) { // the module uses one of two addresses
oled.clearDisplay();
oled.setTextColor(SSD1306_WHITE);
oled.setCursor(0, 0); oled.print("BME280 not found");
oled.display();
while (true) {}
}
}
void loop() {
if (millis() - lastDraw >= 2000) {
lastDraw = millis();
float t = bme.readTemperature();
float h = bme.readHumidity();
float p = bme.readPressure() / 100.0F; // hPa
oled.clearDisplay();
oled.setTextColor(SSD1306_WHITE);
oled.setTextSize(1);
oled.setCursor(0, 0); oled.print("Weather node");
oled.setTextSize(2);
oled.setCursor(0, 14); oled.print(t, 1); oled.print(" C");
oled.setCursor(0, 34); oled.print(h, 0); oled.print(" % RH");
oled.setTextSize(1);
oled.setCursor(0, 56); oled.print(p, 1); oled.print(" hPa");
oled.display();
if (!sentFirst || millis() - lastSend >= 60000UL) {
sentFirst = true;
lastSend = millis();
Serial.print("T="); Serial.print(t, 1);
Serial.print(" C, RH="); Serial.print(h, 0);
Serial.print(" %, P="); Serial.print(p, 1);
Serial.println(" hPa");
}
}
}What the serial monitor should show
Open the serial monitor at the baud rate in the code. This is what our simulator prints for a virtual STM32 Blue Pill (F103C8) with its sensors at their default values. Your numbers will follow your real readings, but the format should match.
T=24.2 C, RH=52 %, P=1008.5 hPa
Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| Room conditions | Plausible temperature and humidity |
| Breathe near the sensor | Humidity rises briefly |
| Move the sensor away from the board | Temperature reads a little lower |
| Serial monitor open | One line per minute |
| Cover the sensor | Readings move slowly |
If it does not work
BME280 not found
Check SDA, SCL and the 3.3 V supply, and the module is a BME280 and not a BMP280.
No serial output
Check USB support is set to CDC, and the port is selected.
Temperature reads high
Move the sensor away from the board and the regulator.
Garbled text
Set the monitor to 115200.
Upload fails
Check the ST-Link wires and boot jumpers.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the blue Pill weather node?
STM32 Blue Pill (STM32F103C8T6), ST-Link V2 programmer (clone), BME280 Environmental Sensor, SSD1306 OLED Display and Breadboard 830 Tie Points.
How long does the blue Pill weather node take to build?
About 150 minutes for a intermediate maker, in 7 steps.
How do I know the blue Pill weather node works?
Room conditions: Plausible temperature and humidity. Breathe near the sensor: Humidity rises briefly. Move the sensor away from the board: Temperature reads a little lower.
BME280 not found: what should I check?
Check SDA, SCL and the 3.3 V supply, and the module is a BME280 and not a BMP280.
No serial output: what should I check?
Check USB support is set to CDC, and the port is selected.
Temperature reads high: what should I check?
Move the sensor away from the board and the regulator.
Garbled text: what should I check?
Set the monitor to 115200.