Learn / Power / Charging

Li-ion Charging and Power Safety

ReviewedIntermediate MakerAbout 6 min
LM2596
In short

Li-ion Charging and Power Safety: the short answer

2 V, then constant voltage while the current falls. A charger chip such as the TP4056 does this for you.

Level
Intermediate
Time
About 6 min
Topic
Power
You will learn to

Charge a Li-ion cell safely and protect a project from short circuits and reverse polarity.

Before this: Batteries: Voltage, Capacity and Runtime

Lithium-ion cells are charged in two stages: constant current until the cell reaches 4.2 V, then constant voltage while the current falls. A charger chip such as the TP4056 does this for you. The common TP4056 module charges at up to 1 A, set by a resistor on the board; small cells need a lower current, roughly half their capacity per hour (0.5C), so a 500 mAh cell wants about 250 mA.

Buy TP4056 modules with the protection chip (usually a DW01 and two small MOSFETs, marked as having OUT+ and OUT− pads). Protection disconnects the cell if it is over-discharged (around 2.4 to 3.0 V), over-charged or shorted. Never charge a cell that is swollen, damaged or very cold, and do not leave charging projects unattended on anything that can burn.

For the rest of the circuit: add a fuse or polyfuse sized a little above normal current, put a Schottky diode (such as a 1N5819) or a P-MOSFET in series for reverse-polarity protection, and keep battery wires short and well insulated. Shorting a Li-ion cell can deliver tens of amps and start a fire in seconds.

Constant current, then constant voltage

A single Li-ion cell is charged with a limited current until it reaches 4.2 V, then held at 4.2 V while the current falls away. Charging beyond 4.2 V or with too much current damages the cell and can start a fire. A charger such as the TP4056 module does this stage by stage, with the current set by one resistor.

A common safe rate is 0.5 C or lower, so a 2000 mAh cell charges at about 1 A at most. Slower is gentler on the cell.

Protection circuits

A protection board, using chips like the DW01 with a pair of MOSFETs, disconnects the cell on over-charge, over-discharge and short circuit. Use cells that have one, or add a module, and do not run a cell below about 3 V. A TP4056 module without the protection chip charges but does not guard the load against deep discharge.

Never charge a swollen, dented or hot cell. Do not charge unattended on a flammable surface, and use cells from known sources with real ratings.

Wiring to the project

A loaded cell can supply a high current, so use a fuse or protection that suits the wire, and make sure reverse polarity is impossible with a keyed connector. Keep metal objects away from the terminals.

Common mistakes
  • Charging with an unprotected module and discharging the cell too deeply.
  • Using a fast charge current on a small cell.
  • Continuing to use a cell that has swollen or been punctured.
Key formulas
I = C × 0.5
gentle charge current, with C the cell capacity in amp-hours
Vfull = 4.2 V
constant-voltage limit of one Li-ion cell
Intermediate lesson · Maker plan

Practise this lesson with Maker

The explanation above is free for everyone. The practice for Intermediate lessons in every domain are part of the Maker plan at ₹499 a month, and Pro includes them too.

With Maker you also get: a worked example, a hands-on task, a 3-question check.

Common questions

What will I learn in "Li-ion Charging and Power Safety"?

Charge a Li-ion cell safely and protect a project from short circuits and reverse polarity.