Tools / Linear Regulator Dissipation
How to work out linear regulator heat
A linear regulator burns off the extra voltage as heat. Here is how much, with your numbers.
Pheat ≈ (Vin − Vout)I; ignores quiescent consumption
Result
- Heat (approx.)
- 1.4 W
- Load
- 1 W
- Ideal efficiency
- 41.67 %
What this leaves out
- Does not establish regulator stability, dropout, thermal resistance or package temperature.
Step by step
The working with your numbers
- Find the voltage the regulator drops
Vdrop = Vin − Vout = 12 − 5 = 7 V - Multiply by the current
P = Vdrop × I = 7 × 0.2 = 1.4 WAll of this turns into heat in the regulator. - Efficiency
Vout ÷ Vin = 5 ÷ 12 = 41.7 % - Temperature rise with no heatsink (TO-220, about 50 °C per watt)
ΔT ≈ 1.4 W × 50 = 70 °C, so about 95 °C in a 25 °C room
Does the answer make sense?
- OK: About 95 °C: too hot to touch but inside the regulator's 125 °C limit. A small heatsink makes it last longer.
- OK: 7 V of headroom is enough for a 7805 (needs about 2 V).
Pick a real part
- 1.4 W is wasted. A buck converter would waste only about 150 mW at 85 % efficiency.
Common mistakes
- Thinking the regulator only uses the output power. The extra voltage times the current all becomes heat.
- Feeding 12 V into a 3.3 V regulator for a Wi-Fi board. 8.7 V × 0.3 A is 2.6 W of heat.
- Forgetting dropout. Most regulators need 1 to 2 V more at the input than the output.
Learn it, try it, build it
Calculated, not measured. Check the exact part datasheet and your real circuit before powering anything.
Just need the number? Use the linear regulator dissipation calculator on Geekobot.
Common questions
How do you work out the heat in a linear regulator?
Multiply the voltage it drops by the current: P = (Vin − Vout) × I. A 7805 from 12 V at 0.2 A makes 7 × 0.2 = 1.4 W of heat.
When does a 7805 need a heatsink?
From about 1 W. A TO-220 package rises about 50 °C per watt in open air, so 1.4 W puts it near 95 °C, which works but is too hot to touch. Above 2 W it reaches its 125 °C limit without a heatsink.