Tools / 555 monostable pulse width

How to work out a 555 monostable pulse width

One trigger gives one pulse of a fixed length. The length is set by a resistor and capacitor, T = 1.1 × R × C.

T = 1.1 × R × C

Inputs

Ω
µF

Results update as you type. Prefixes work: 4.7k, 100u, 10n.

Result
Pulse width
1.1 s
Shortest pulse
836 ms
Longest pulse
1.386 s
Step by step

The working with your numbers

  1. Change the capacitance to faradsC = 10 µF ÷ 1,000,000 = 10⁻⁵ F
  2. Multiply by 1.1T = 1.1 × R × C = 1.1 × 100,000 × 10⁻⁵ = 1.1 sThe 555 ends the pulse when the capacitor reaches two thirds of the supply: ln 3 = 1.0986 time constants.
  3. The triggerA brief low pulse on pin 2 (below ⅓ of the supply) starts it. The output goes high for 1.1 s, then drops.
  4. Worst case with 5 % R and ±20 % C836 ms to 1.39 s

Does the answer make sense?

  • OK: Shortcut: the pulse is just over one time constant (R × C = 1 s), 10 % longer.
  • OK: The trigger pulse must be shorter than 1.1 s. If it stays low longer, the output stays high until it releases.
  • OK: The pulse width does not depend on the supply voltage, because the thresholds are fractions of it.

Pick a real part

  • Nearest standard values: R = 100 kΩ (E24), C = 10 µF (E12), giving 1.1 s.
  • Use a 100 nF capacitor across the control pin (5) to ground and a 100 µF across the supply. For accurate pulses use a film capacitor instead of an electrolytic.

Common mistakes

  • Using the astable formula. A monostable uses T = 1.1 R C, with no second resistor.
  • Holding the trigger low for longer than the pulse. The output then stays high.
  • Forgetting that an electrolytic capacitor leaks, which stretches long pulses and makes them drift.

Learn it, try it, build it

Calculated, not measured. Check the exact part datasheet and your real circuit before powering anything.

Common questions

How do you work out a 555 monostable pulse width?

T = 1.1 × R × C. With 100 kΩ and 10 µF: 1.1 × 100,000 × 0.00001 = 1.1 seconds.

How can I make a 555 monostable pulse longer?

Raise R or C. Keep R under about 3 MΩ and use a low-leakage capacitor. For minutes or hours, divide an astable with a counter instead.