Tools / 555 Astable Frequency
How to work out a 555 timer frequency
The capacitor charges through R1 and R2 and empties through R2 only. Here is the working with your numbers.
f ≈ 1.44 / ((R1 + 2·R2)·C); duty = (R1+R2)/(R1+2R2)
Result
- Frequency
- 68.57 Hz
- Duty cycle
- 52.38 %
- High time
- 7.623 ms
- Low time
- 6.93 ms
What this leaves out
- Bipolar 555 estimate; CMOS versions and tolerances change the result.
- In this circuit the duty cycle is always above 50%. For 50% or below, add a diode across R2.
Step by step
The working with your numbers
- Change the capacitance to farads
C = 1 µF ÷ 1,000,000 = 10⁻⁶ F - High time: charging through R1 and R2
t_high = 0.693 × (R1 + R2) × C = 0.693 × 11,000 × 10⁻⁶ = 7.62 ms - Low time: emptying through R2 only
t_low = 0.693 × R2 × C = 0.693 × 10,000 × 10⁻⁶ = 6.93 ms - Add them for one full cycle
T = 7.62 ms + 6.93 ms = 14.6 ms - Frequency is 1 over the period
f = 1 ÷ 0.0146 = 68.7 Hz - Duty cycle
t_high ÷ T = 52.4 %
See it
The output waveform
Does the answer make sense?
- OK: Shortcut check: f = 1.44 ÷ ((R1 + 2R2) × C) = 68.6 Hz. That matches, apart from rounding in 0.693 and 1.44.
- OK: The duty is always over 50 % in this circuit because the high time includes R1. For under 50 %, put a diode across R2.
Pick a real part
- Nearest standard values: R1 = 1 kΩ, R2 = 10 kΩ, C = 1 µF, giving 68.6 Hz.
- Capacitor tolerance (often ±20 %) moves the frequency by the same amount. Use a film capacitor for steadier timing.
Common mistakes
- Using R1 + R2 for both halves. The low time only uses R2.
- Forgetting to change µF to farads.
- Expecting a 50 % square wave. Make R2 much bigger than R1 to get close, or add a diode across R2.
Learn it, try it, build it
Calculated, not measured. Check the exact part datasheet and your real circuit before powering anything.
Just need the number? Use the 555 astable frequency calculator on Geekobot.
Common questions
How do you work out a 555 timer's frequency?
f = 1.44 ÷ ((R1 + 2 × R2) × C). With R1 = 1 kΩ, R2 = 10 kΩ and C = 1 µF: 1.44 ÷ (21,000 × 0.000001) ≈ 68.6 Hz.
Why is the 555 duty cycle always more than 50 %?
The capacitor charges through R1 and R2 but discharges through R2 only, so the high time is always longer. A diode across R2 lets it charge through R1 alone.