Tools / Wire gauge (AWG), current and voltage drop

How to choose a wire gauge (AWG) for a current and length

Thicker wire has less resistance and carries more current. Here are the numbers for your gauge, length and current.

d = 0.127 × 92^((36 − AWG) ÷ 39) mm; R = ρL ÷ A; ΔV = I × R

Inputs

AWG
A
m
V

Results update as you type. Prefixes work: 4.7k, 100u, 10n.

Result
Voltage drop
635.5 mV
Drop
5.296 %
Power loss
1.271 W
Resistance per m
52.96 mΩ
Diameter (mm)
0.6438033
Area mm2
0.3255339
Safe current
1.3 A
Awg for current
20
What this leaves out
  • 2 A is above about 1.3 A, a safe level for hook-up wire bundled in a harness. Use a thicker wire.
  • The drop is above 5 % of the supply. Use thicker or shorter wire.
Step by step

The working with your numbers

  1. Diameter from the gauged = 0.127 mm × 92^((36 − 22) ÷ 39) = 0.644 mmAWG numbers go up as the wire gets thinner. Six gauges down roughly halves the area.
  2. Cross-section areaA = π × d² ÷ 4 = 0.326 mm²
  3. Resistance per metre of copperρ ÷ A = 0.017241 ÷ 0.326 = 0.053 Ω/mCopper at 20 °C. It rises by about 0.4 % per °C.
  4. Round trip: current goes out and backR = 0.053 × 2 × 3 m = 318 mΩ
  5. Voltage lost in the wireΔV = I × R = 2 × 0.318 = 0.636 V = 5.3 % of 12 V
  6. Heat in the wireP = I² × R = 1.27 W

Does the answer make sense?

  • Watch out: The drop is 5.3 % of the supply. Aim for under 5 %, and under 2 % for a motor or LED strip at the far end.
  • Watch out: 2 A is more than about 1.3 A. The wire would warm up. 20 AWG or thicker suits.

Pick a real part

  • For 2 A in a bundled lead, 20 AWG is the thinnest sensible gauge; go one or two sizes thicker for margin.
  • Common hook-up wire: 26 AWG for signals, 22 AWG up to about 3 A, 18 AWG up to about 7 A, 14 AWG up to about 15 A. Stranded wire is easier on the bench; its ampacity is the same for the same gauge.
  • Mains wiring has its own rules and must follow the local code, not this estimate.

Common mistakes

  • Forgetting the return path. The current goes out and back, so use twice the one-way length.
  • Choosing by the insulation rating or the wire's colour. The current limit comes from the copper area and heat.
  • Treating the safe current as exact. Bundles, hot spots and long runs lower it.

Learn it, try it, build it

Calculated, not measured. Check the exact part datasheet and your real circuit before powering anything.

Common questions

How do you find a wire's resistance from its AWG number?

Diameter d = 0.127 × 92^((36 − AWG) ÷ 39) mm, area = π d² ÷ 4, and resistance per metre = 0.017241 Ω·mm²/m ÷ area. 22 AWG is 0.326 mm², so about 0.053 Ω per metre.

What AWG do I need for 5 A?

As a conservative rule for bundled hook-up wire, about 4 A per mm², so 5 A needs at least 1.25 mm², which is 16 AWG. Use a thicker wire for long runs so the voltage drop stays small.