Tools / Wire gauge (AWG), current and voltage drop
How to choose a wire gauge (AWG) for a current and length
Thicker wire has less resistance and carries more current. Here are the numbers for your gauge, length and current.
d = 0.127 × 92^((36 − AWG) ÷ 39) mm; R = ρL ÷ A; ΔV = I × R
Result
- Voltage drop
- 635.5 mV
- Drop
- 5.296 %
- Power loss
- 1.271 W
- Resistance per m
- 52.96 mΩ
- Diameter (mm)
- 0.6438033
- Area mm2
- 0.3255339
- Safe current
- 1.3 A
- Awg for current
- 20
What this leaves out
- 2 A is above about 1.3 A, a safe level for hook-up wire bundled in a harness. Use a thicker wire.
- The drop is above 5 % of the supply. Use thicker or shorter wire.
Step by step
The working with your numbers
- Diameter from the gauge
d = 0.127 mm × 92^((36 − 22) ÷ 39) = 0.644 mmAWG numbers go up as the wire gets thinner. Six gauges down roughly halves the area. - Cross-section area
A = π × d² ÷ 4 = 0.326 mm² - Resistance per metre of copper
ρ ÷ A = 0.017241 ÷ 0.326 = 0.053 Ω/mCopper at 20 °C. It rises by about 0.4 % per °C. - Round trip: current goes out and back
R = 0.053 × 2 × 3 m = 318 mΩ - Voltage lost in the wire
ΔV = I × R = 2 × 0.318 = 0.636 V = 5.3 % of 12 V - Heat in the wire
P = I² × R = 1.27 W
Does the answer make sense?
- Watch out: The drop is 5.3 % of the supply. Aim for under 5 %, and under 2 % for a motor or LED strip at the far end.
- Watch out: 2 A is more than about 1.3 A. The wire would warm up. 20 AWG or thicker suits.
Pick a real part
- For 2 A in a bundled lead, 20 AWG is the thinnest sensible gauge; go one or two sizes thicker for margin.
- Common hook-up wire: 26 AWG for signals, 22 AWG up to about 3 A, 18 AWG up to about 7 A, 14 AWG up to about 15 A. Stranded wire is easier on the bench; its ampacity is the same for the same gauge.
- Mains wiring has its own rules and must follow the local code, not this estimate.
Common mistakes
- Forgetting the return path. The current goes out and back, so use twice the one-way length.
- Choosing by the insulation rating or the wire's colour. The current limit comes from the copper area and heat.
- Treating the safe current as exact. Bundles, hot spots and long runs lower it.
Learn it, try it, build it
Calculated, not measured. Check the exact part datasheet and your real circuit before powering anything.
Common questions
How do you find a wire's resistance from its AWG number?
Diameter d = 0.127 × 92^((36 − AWG) ÷ 39) mm, area = π d² ÷ 4, and resistance per metre = 0.017241 Ω·mm²/m ÷ area. 22 AWG is 0.326 mm², so about 0.053 Ω per metre.
What AWG do I need for 5 A?
As a conservative rule for bundled hook-up wire, about 4 A per mm², so 5 A needs at least 1.25 mm², which is 16 AWG. Use a thicker wire for long runs so the voltage drop stays small.