Pi probe temperature log to a file
A Raspberry Pi 4 reads a DS18B20 probe on the one-wire bus and writes a timestamped line to a CSV file each minute, ready to open in a spreadsheet.
Build it step by step
0 of 7 doneShut the Pi down
Then unplug power.
Wire the probe
Red to pin 1, black to pin 6, yellow to pin 7.
Add the pull-up
4.7 kilo-ohm from pin 7 to pin 1.
Enable one-wire
raspi-config, then reboot.
Check the probe
ls /sys/bus/w1/devices shows a 28 folder.
Run the program
A line prints each minute.
Open the CSV
Chart it in a spreadsheet.
How do you build a pi probe temperature log to a file?
A Raspberry Pi 4 reads a DS18B20 probe on the one-wire bus and writes a timestamped line to a CSV file each minute, ready to open in a spreadsheet. You need Raspberry Pi 4 Model B (4 GB), DS18B20 waterproof probe, Resistor 4.7 kΩ and Breadboard 830 Tie Points. It takes 7 steps and about 120 minutes.
- Level
- Intermediate
- Time
- About 120 min
- Parts
- 4
Parts list
- Single Board ComputersBuy
- SensorsBuy
- PassivesBuyResistor 4.7 kΩ × 1
- PrototypingBuy
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| DS18B20 red | Pi pin 1 (3.3 V) | Power at 3.3 V |
| DS18B20 black | Pi pin 6 (GND) | Ground |
| DS18B20 yellow | Pi pin 7 (GPIO4) | One-wire data |
| 4.7 kilo-ohm resistor | Between GPIO4 and 3.3 V | Pull-up for the data line |
Code
The Pi has built-in support for the DS18B20 one-wire probe. Once the interface is on, the kernel finds the probe, and each probe shows up as a folder whose name starts with 28 and holds a small text file with the latest reading. The first line ends with YES when the checksum is good, and the second ends with t equals the temperature in thousandths of a degree. The program reads that file, ignores a bad checksum, and appends a line with a timestamp to a CSV file once a minute, which any spreadsheet can open and chart. The 4.7 kilo-ohm resistor pulls the data line up to 3.3 V, since the probe only pulls the line low. Readings are indicative only: a probe in air follows the temperature slowly and its metal tip must touch what you are measuring. Do not use it for food safety or medical decisions.
# Enable the one-wire interface first: sudo raspi-config nonint do_onewire 0 then reboot
import glob, time, datetime
LOG = "/home/pi/temperature_log.csv" # change pi to your user name
def read_probe():
files = glob.glob("/sys/bus/w1/devices/28-*/w1_slave")
if not files:
return None
with open(files[0]) as f:
lines = f.read().splitlines()
if len(lines) < 2 or not lines[0].endswith("YES"): # YES means the checksum is good
return None
return int(lines[1].split("t=")[1]) / 1000.0
with open(LOG, "a") as f:
if f.tell() == 0:
f.write("time,celsius\n")
while True:
t = read_probe()
if t is not None:
stamp = datetime.datetime.now().isoformat(timespec="seconds")
with open(LOG, "a") as f:
f.write("{},{:.2f}\n".format(stamp, t))
print(stamp, "{:.2f}".format(t))
time.sleep(60)Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| Probe in air | Room temperature |
| Probe in warm water | Value rises |
| Checksum error | Line is skipped, no crash |
| CSV file | Header and one line per minute |
| After reboot | Appends to the same file |
If it does not work
No 28 folder
Check the one-wire interface is on and the pull-up is fitted.
Reads 85 degrees
The probe has just powered up, wait for the next reading.
File not found
Change the LOG path to your home folder.
Permission error
Run as your own user and check the folder exists.
No lines written
Look for the checksum YES in the device file.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the pi probe temperature log to a file?
Raspberry Pi 4 Model B (4 GB), DS18B20 waterproof probe, Resistor 4.7 kΩ and Breadboard 830 Tie Points.
How long does the pi probe temperature log to a file take to build?
About 120 minutes for a intermediate maker, in 7 steps.
How do I know the pi probe temperature log to a file works?
Probe in air: Room temperature. Probe in warm water: Value rises. Checksum error: Line is skipped, no crash.
No 28 folder: what should I check?
Check the one-wire interface is on and the pull-up is fitted.
Reads 85 degrees: what should I check?
The probe has just powered up, wait for the next reading.
File not found: what should I check?
Change the LOG path to your home folder.
Permission error: what should I check?
Run as your own user and check the folder exists.