Build it step by step
0 of 6 doneDraw the ladder
Sketch the control rung with STOP in series, START in parallel with the hold-in contact, then the coil.
Wire the coil
Connect the relay coil with its flyback diode and test it with a temporary link.
Add the hold-in
Wire contact set 1 across the START button.
Add the stop button
Put the normally-closed stop button in series with the control supply.
Wire the motor
Feed the motor through contact set 2 with its own diode.
Test the sequence
Press start and release, then stop, and watch the motor and relay.
How do you build a motor start-stop with relays?
A classic hold-in relay circuit starts a 12 V motor with one button and stops it with another. You need Relay 24 V DPDT (MY2N), Push button 16 mm metal (momentary, LED) × 2, Johnson geared motor 300 RPM 12 V, 12 V 2 A DC adapter, Rectifier Diode 1N4007 × 2 and Terminal block 12-way (barrier strip). It takes 6 steps and about 60 minutes.
- Level
- Beginner
- Time
- About 60 min
- Parts
- 6
Parts list
Tick what you already own. It saves to My Garage, so “Build with what I have” knows.
Wiring
| From | To | Why |
|---|---|---|
| 12 V adapter + | Stop button (normally closed) | Supply through the stop button |
| Stop button other side | Start button (normally open) and relay contact set 1 NO | Control node |
| Start button other side and contact set 1 COM | Joined to the relay coil + terminal | Hold-in path |
| Relay coil - terminal | 12 V adapter - | Return |
| 1N4007 diode | Across the relay coil, cathode to coil + | Flyback diode |
| 12 V adapter + (before the stop button) | Relay contact set 2 COM | Motor supply |
| Relay contact set 2 NO | Motor + | Switched motor feed |
| Motor - | 12 V adapter - | Return |
| 1N4007 diode | Across the motor, cathode to motor + | Motor flyback diode |
No code needed
No code, only relay logic. Use a relay with a 12 V coil (a 24 V coil relay will not pull in properly on 12 V) and a stop button with a normally-closed contact: pressing it breaks the control supply. When START is pressed, the coil energises and contact set 1 closes across the START button, so the coil stays powered after release (the hold-in or seal-in). Contact set 2 feeds the motor. Pressing STOP drops the coil and the motor stops. Keep the motor current under the relay and adapter rating (a stalled motor can draw several amps). Any mains control must be wired by a qualified electrician; this build stays at 12 V.
Test checklist
What you should see at each check. If a reading is far off, stop and use the troubleshooting list.
| Check | Expected |
|---|---|
| Press START | Relay clicks in and the motor runs |
| Release START | Motor keeps running |
| Press STOP | Relay drops and the motor stops |
| Press START without release | Same as above |
If it does not work
Relay drops when START is released
The hold-in contact is not wired across START.
Relay does not click
Check the coil voltage and the stop button type.
Motor does not run
Check contact set 2 wiring and the supply.
Relay buzzes
Voltage is too low. Use a proper 12 V adapter.
Still stuck? Find the fault step by step with your multimeter →
Common questions
What parts do I need for the motor start-stop with relays?
Relay 24 V DPDT (MY2N), Push button 16 mm metal (momentary, LED) × 2, Johnson geared motor 300 RPM 12 V, 12 V 2 A DC adapter, Rectifier Diode 1N4007 × 2 and Terminal block 12-way (barrier strip).
How long does the motor start-stop with relays take to build?
About 60 minutes for a beginner maker, in 6 steps.
How do I know the motor start-stop with relays works?
Press START: Relay clicks in and the motor runs. Release START: Motor keeps running. Press STOP: Relay drops and the motor stops.
Relay drops when START is released: what should I check?
The hold-in contact is not wired across START.
Relay does not click: what should I check?
Check the coil voltage and the stop button type.
Motor does not run: what should I check?
Check contact set 2 wiring and the supply.
Relay buzzes: what should I check?