Lab / Virtual lab / Transients

RL current rise

Measure how current builds up in an inductor and find the time constant L/R.

TransientsSimulated

Circuit

Updates as you change values
5 VR 470 ΩL47 mHV

A 5 V step applied to a resistor and inductor in series; read the current from the voltage across the resistor.

Controls

Changing any setting except time after switch-on starts a new set of readings.

Meters

Current6.72 mA
Inductor voltage1.84 V

Graph

0 readings

Your graph appears here

Take readings, or press Auto sweep to log a full set.

your readings

Theory

  • i(t) = (V/R)(1 − e^(−t/τ)), τ = L / R
  • vL(t) = L di/dt = V e^(−t/τ)
  • Final current I = V / R (the inductor is then a short)
  • Energy stored W = ½ L I²; opening the switch suddenly gives a big back-EMF

Worked out for your values

Time constant τ
100 µs
Final current
10.64 mA
Current now
6.725 mA
vL now
1.839 V
Energy at full current
2.66 µJ

Your result

Worked out from your readings and compared with theory.

τ from the 63.2 % point

Take readings either side of 63 % of the final current.

Sources of error

  • The coil's own winding resistance adds to R
  • Inductor tolerance (often ±10 %)
  • Core saturation at high current lowers L