Lab / RGPV / Analog and linear ICs / Experiment 5

Instrumentation amplifier (three op-amp)

Analog and linear ICsVirtual readings4 viva questionsRecord book ready
Aim

To build a three op-amp instrumentation amplifier and verify its gain for different values of Rg.

Apparatus
  • IC LM324 (or three 741s)
  • Resistors 10 kΩ × 7
  • Potentiometer for Rg
  • Dual supply ±12 V
  • DC sources
−+Vout = −Rf/Rin · Vin

Theory

Two input buffers give very high input resistance; a difference amplifier rejects the common-mode signal. With equal resistors R in the first stage and a gain resistor Rg between them, and a unity-gain difference stage: Vo = (1 + 2R/Rg)(V2 − V1). Changing one resistor (Rg) sets the gain without upsetting the balance.

Read the lesson: Sensor interfaces ›
Circuit connections
  • V1 and V2 into the non-inverting inputs of A1 and A2; R from each output back to its inverting input; Rg between the two inverting inputs
  • A1 and A2 outputs into a unity-gain difference amplifier (A3)

Procedure

Pre-lab check

4 questions · 75% to be ready
1Why is an instrumentation amplifier used for sensors?
2How is gain changed?
3Name a single-chip instrumentation amplifier.
4What limits CMRR in the three op-amp circuit?

Try the readings before the lab

Calculated, not measured. In the lab, write down your own readings.
Rg (kΩ)GainVo (V)
1212.1
2.210.091.009
4.75.260.526
1030.3
221.910.191

Precautions

  • Match the resistors closely (1%) for good CMRR.
  • Keep the inputs within the common-mode range.

My readings

Type what you measured. It goes into your record book, and to My Garage when you are signed in.

S. No.Rg (kΩ)GainVo (V)
1
2
3
4
5
6

Check my readings

Put the value you set in the first column, then compare. Real parts have tolerance.

Open my record book
Result

Gain follows 1 + 2R/Rg: for Rg = ___ kΩ, gain = ___ (theory ___). Common-mode output ≈ ___ mV.

Everything above is free. The print-ready write-up comes with Maker.

Printed pages leave the observation table empty for your own readings.

Viva questions

Say your answer out loud first, then check. The first 2 answers are free; Maker opens all 4.

1. Why is an instrumentation amplifier used for sensors?
2. How is gain changed?
3. Name a single-chip instrumentation amplifier.
4. What limits CMRR in the three op-amp circuit?

Quick answers for your record and viva

What is the aim of the instrumentation amplifier (three op-amp) experiment?

To build a three op-amp instrumentation amplifier and verify its gain for different values of Rg.

What apparatus is needed for instrumentation amplifier (three op-amp)?

IC LM324 (or three 741s), Resistors 10 kΩ × 7, Potentiometer for Rg, Dual supply ±12 V, DC sources.

What is the theory behind instrumentation amplifier (three op-amp)?

Two input buffers give very high input resistance; a difference amplifier rejects the common-mode signal. With equal resistors R in the first stage and a gain resistor Rg between them, and a unity-gain difference stage: Vo = (1 + 2R/Rg)(V2 − V1). Changing one resistor (Rg) sets the gain without upsetting the balance.

What result should I get in instrumentation amplifier (three op-amp)?

Gain follows 1 + 2R/Rg: for Rg = ___ kΩ, gain = ___ (theory ___). Common-mode output ≈ ___ mV.

What precautions should I take in instrumentation amplifier (three op-amp)?

Match the resistors closely (1%) for good CMRR. Keep the inputs within the common-mode range.