Fault finder: Zener regulation test
5 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 5 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 5
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Output about 0.7 V: what should I check?
The Zener is the wrong way round, swap it.
Output equals the battery voltage: what should I check?
The Zener is not connected to ground.
Output never reaches 5 V: what should I check?
Check for a load left connected or a weak battery.
Resistor or Zener warm: what should I check?
Check the resistor value is 330 ohm and the load is not a short.
Readings vary: what should I check?
Check the breadboard contacts.