Fault finder: Zener regulation test

5 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 5 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 5

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Output about 0.7 V: what should I check?

The Zener is the wrong way round, swap it.

Output equals the battery voltage: what should I check?

The Zener is not connected to ground.

Output never reaches 5 V: what should I check?

Check for a load left connected or a weak battery.

Resistor or Zener warm: what should I check?

Check the resistor value is 330 ohm and the load is not a short.

Readings vary: what should I check?

Check the breadboard contacts.