Fault finder: Push-pull force gauge

11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Readings drift: what should I check?

Let the HX711 warm up and avoid touching the cell during tare.

Sign backwards: what should I check?

Swap the white and green wires.

Noisy readings: what should I check?

Use shorter wires and average more samples.

Not accurate: what should I check?

Calibrate again with a mass near what you will measure.