Fault finder: Push-pull force gauge
11 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 11 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 11
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Readings drift: what should I check?
Let the HX711 warm up and avoid touching the cell during tare.
Sign backwards: what should I check?
Swap the white and green wires.
Noisy readings: what should I check?
Use shorter wires and average more samples.
Not accurate: what should I check?
Calibrate again with a mass near what you will measure.