Fault finder: LED VU meter with LM3914
10 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
All LEDs lit: what should I check?
Reference or RLO wiring is wrong. Check pins 4, 6, 7 and 8.
No LEDs ever: what should I check?
The signal is too small. Turn the pot up or use the phone at a higher volume.
LEDs flicker too fast: what should I check?
The peak detector decays quickly. Use a larger capacitor.
Chip too hot: what should I check?
Use dot mode, a lower supply or a bigger R_ref.