Fault finder: LED VU meter with LM3914

10 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 10 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 10

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

All LEDs lit: what should I check?

Reference or RLO wiring is wrong. Check pins 4, 6, 7 and 8.

No LEDs ever: what should I check?

The signal is too small. Turn the pot up or use the phone at a higher volume.

LEDs flicker too fast: what should I check?

The peak detector decays quickly. Use a larger capacitor.

Chip too hot: what should I check?

Use dot mode, a lower supply or a bigger R_ref.