Fault finder: Thermistor bridge temperature alarm
7 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Buzzer always on: what should I check?
Pot wiper is below node A. Turn it up.
Buzzer never sounds: what should I check?
Check which way the pot turns and that the NTC is on the + side of the divider.
Buzzer chatters: what should I check?
The 100 kΩ hysteresis resistor is missing or on the wrong pin.
Buzzer quiet: what should I check?
The buzzer is too low in voltage rating. Use one rated for 9 V.