Fault finder: Function generator with DDS

12 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 12 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 12

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

No output: what should I check?

Check FSYNC and that the module has power.

Wrong frequency: what should I check?

Check the module crystal frequency.

Distorted wave: what should I check?

Use a high-impedance load.