Fault finder: Shower timer for saving water
9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Litres off by 10 to 20 percent: what should I check?
Calibrate with a bucket, because flow rate changes the count a little.
No pulses: what should I check?
Check the flow direction arrow on the sensor and the signal wire on D2.
Display not changing: what should I check?
CLK and DIO are swapped.
Leak at the fitting: what should I check?
Re-do the PTFE tape and tighten by hand plus a quarter turn.