Fault finder: Shower timer for saving water

9 checks for this build on the Nano. Work from the top: power first, then each part, then the code.

0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9

Nano supply pin

Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Litres off by 10 to 20 percent: what should I check?

Calibrate with a bucket, because flow rate changes the count a little.

No pulses: what should I check?

Check the flow direction arrow on the sensor and the signal wire on D2.

Display not changing: what should I check?

CLK and DIO are swapped.

Leak at the fitting: what should I check?

Re-do the PTFE tape and tighten by hand plus a quarter turn.