Fault finder: Sapling watering reminder
9 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 9 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 9
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
LED never blinks: what should I check?
DRY_LIMIT is too high or too low for your 3 V readings. Check the numbers.
Sensor corrodes: what should I check?
It must be powered only while reading, as in the code.
Board resets constantly: what should I check?
The supply is too low. Use fresh cells.
Cannot upload: what should I check?
Replug the board after clicking upload. The bootloader waits only a few seconds.