Fault finder: RC time constant lab
8 checks for this build on the board. Work from the top: power first, then each part, then the code.
0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8
board supply pin
Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Voltage rises far too slowly or stops short: what should I check?
The capacitor leaks or its tolerance is wide. Try another.
Reading rises then falls: what should I check?
The meter is draining the capacitor in a high range. Use the 10 MΩ input range.
Nothing happens: what should I check?
The capacitor is backwards or the button is not closing.
Capacitor gets warm or smells: what should I check?
It is connected backwards. Disconnect the battery at once.