Fault finder: RC time constant lab

8 checks for this build on the board. Work from the top: power first, then each part, then the code.

0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8

board supply pin

Plug the board into USB. Black probe on a GND pin, red probe on the 5V pin of the board.

You should see: 4.6 to 5.3 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Voltage rises far too slowly or stops short: what should I check?

The capacitor leaks or its tolerance is wide. Try another.

Reading rises then falls: what should I check?

The meter is draining the capacitor in a high range. Use the 10 MΩ input range.

Nothing happens: what should I check?

The capacitor is backwards or the button is not closing.

Capacitor gets warm or smells: what should I check?

It is connected backwards. Disconnect the battery at once.