Fault finder: Rain alert for the clothesline
8 checks for this build on the Nano. Work from the top: power first, then each part, then the code.
0 of 8 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 8
Nano supply pin
Plug the Nano into USB. Black probe on a GND pin, red probe on the 5V pin of the board.
You should see: 4.6 to 5.3 V
Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.
Common faults in this build
Always says rain: what should I check?
Turn the module trimmer the other way, or dry the plate.
Never says rain: what should I check?
Check the plate wires reach the module and DO goes to D5.
The plate turns green over weeks: what should I check?
That is corrosion. Powering it only while reading (as here) slows it. Replace the plate when it gets bad.