Fault finder: Pico W plant moisture web page

7 checks for this build on the Pico. Work from the top: power first, then each part, then the code.

0 of 7 checked
Power🔧 DC volts, 20 V rangeCheck 1 of 7

Pico supply pin

Plug the Pico into USB. Black probe on a GND pin, red probe on the 3V3(OUT) pin of the board.

You should see: 3.15 to 3.45 V

V

Readings are compared with the ranges for this build's parts. A meter on the wrong range or a loose probe gives odd numbers: check those first.

Common faults in this build

Page does not open: what should I check?

Check the address from the shell and that the phone is on the same Wi-Fi.

Wi-Fi does not connect: what should I check?

Check the name and password, and that the network is 2.4 GHz.

Percentage stuck at 0 or 100: what should I check?

Measure the dry and wet readings again and set DRY and WET.

Readings jump around: what should I check?

Keep the sensor still and away from your hands while measuring.

Reading falls for no reason: what should I check?

Water may have reached the electronics above the line, dry the module.